* Displays information or setting entered in the microprocessor Configurations
+ May or may not be displayed depending on Parameter/Configuration settings
DATA
*
PRODUCTSHIELD SETUP:
+
• PRODUCTSHIELD
ECONO:
••
ECONO MIN TEMP
••
ECONO MAX TEMP
••
ECONO DELTA-T
• PRODUCTSHIELD HIGH
AIR:
••
HIGH AIR MIN TEMP
••
HIGH AIR MAX TEMP
••
HIGH AIR DELTA-T
• PRODUCTSHIELD:
WINTER - xx°
*
RANGE 1 LOCK
+
*
•RANGE 1 MINIMUM TEMP
+
*
•RANGE 1 MAXIMUM TEMP Displays maximum temperature setting for Range 1. (Will only be displayed if
+
*
RANGE 2 LOCK
+
*
•RANGE 2 MIN. TEMP
+
*
•RANGE 2 MAX. TEMP
+
*
TEMPERATURE (REMOTE)
+
SENSOR 1 (or 2 or 3)
This will only display when IntelliSet is installed, ProductShield setting is ON
and ECONO, HIGH AIR and/or WINTER is/are NOT OFF.
Displays ProductShield Econo setting (OFF, Go To Start-Stop OR Go To
Continuous Run
Displays minimum temperature setting for activation of ProductShield Econo.
(Will only be displayed if Econo is NOT OFF)
Displays maximum temperature setting for activation of ProductShield Econo.
(Will only be displayed if Econo is NOT OFF)
Displays Delta-T setting for activation of ProductShield Econo. (Will only be
displayed if Econo is NOT OFF)
Indicates if Product Shield High Air is ON or OFF
Displays minimum ambient temperature setting for activation of ProductShield
High Air (Will only be displayed if High Air is ON)
Displays maximum temperature setting for activation of ProductShield High Air
(Will only be displayed if High Air is ON)
Displays Delta-T setting for activation of ProductShield High Air (Will only be
displayed if High Air is ON)
Indicates the ambient temperature below which ProductShield Winter will be
active (Will only be displayed if WINTER is NOT OFF)
This is only displayed when Range Lock 1 is configured ON.
Displays Range Lock 1 setting:
OFF = Temperature Range 1 Lock is turned off.
CONTINUOUS = When the set point is set between Range 1 Minimum & Max-
imum Temperatures, the unit is set to operate only in Continuous.
START-STOP - When the set point is set between Range 1 Minimum & Maxi-
mum Temperatures, the unit is set to operate only in Start-Stop.
Displays minimum temperature setting for Range 1. (Will only be displayed if
Range Lock 1 is ON)
Range Lock 1 is ON)
This is only displayed when Range Lock 1 is configured ON.
Displays Range Lock 1 setting:
OFF = Temperature Range 2 Lock is turned off.
CONTINUOUS = When the set point is set between Range 2 Minimum & Max-
imum Temperatures, the unit is set to operate only in Continuous Run/.
START-STOP = When the set point is set between Range 2 Minimum & Max-
imum Temperatures, the unit is set to operate only in Start-Stop.
Displays minimum temperature setting for Range 2. (Will only be displayed if
Range Lock 2 is ON)
Displays maximum temperature setting for Range 2. (Will only be displayed if
Range Lock 2 is ON)
Will only display when one or more of the optional sensors are configured ON.
Displays temperate reading of remote Temperature Sensor 1 (or 2 or 3).
3-19
DEFINITION
62-61753-21