CONFIGURATION
STANDBY MAXIMUM GENERATOR
AMPS
STARTUP MAXIMUM GENERATOR
AMPS
DIESEL OFFSET MAXIMUM AMPS
STANDBY STARTUP DELAY
DISPLAY TOTAL ENGINE HR
DISPLAY STANDBY RUN HR
DISPLAY TOTAL SWITCH ON HR
DIESEL RESET VALUE
(Refer to Section 8.2 for oil/filter
change intervals.)
STANDBY RESET VALUE
SWITCH ON RESET VALUE
62-61753-21
SELECTIONS
22A
Indicates to the controller the maximum allowable
10 TO 35
amperage in Standby operation.
in 0.5A increments
USE FACTORY DEFAULT SETTING ONLY, DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.
17A
Indicates to the controller the maximum allowable
10 TO 35
amperage during start up.
in 0.5A increments
USE FACTORY DEFAULT SETTING ONLY, DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.
4.0A
Indicates to the controller the maximum allowable
0 TO 10
amperage in low speed operation.
in 0.5A increments
USE FACTORY DEFAULT SETTING ONLY, DO
NOT OPERATE UNIT WITH DIFFERENT SETTING.
OFF
Indicates to the controller the delay for this unit when
5 Seconds
starting in standby.
10 Seconds
This setting is used when multiple units are on the
15 Seconds
same line to stagger the occurrence of high inrush
20 Seconds
current in situations such as restart after a power
loss.
YES / NO
YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour me-
ter menu.
NO = This hour meter will not be displayed during the
startup messaging sequence and will be shown with
the "other meters and counters".
YES / NO
YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour me-
ter menu.
NO = This hour meter will not be displayed during the
startup messaging sequence and will be shown with
the "other meters and counters".
YES / NO
YES = This hour meter will be displayed during the
startup messaging sequence and will be in hour me-
ter menu.
NO = This hour meter will not be displayed during the
startup messaging sequence and will be shown with
the "other meters and counters".
0
When the meter is reset, the value selected here will
be added to the to the present meter reading to indi-
50 TO 30,000
cate to the controller when the next service interval
hours in 50 hour
alarm will be triggered. If the value entered is "0" the
increments
alarm feature is turned off.
0
When the meter is reset, the value selected here will
be added to the to the present meter reading to indi-
50 TO 30,000
cate to the controller when the next service interval
hours in 50 hour
alarm will be triggered. If the value entered is "0" the
increments
alarm feature is turned off.
OFF
When the meter is reset, the value selected here will
be added to the to the present meter reading to indi-
50 TO 30,000
cate to the controller when the next service interval
hours in 50 hour
alarm will be triggered. If the value entered is "0" the
increments
alarm feature is turned off.
5-10
DESCRIPTION