7.3 Maintenance
Replacing the group gasket and the shower screen
Switch off the machine, disconnect the power cord and let the machine cool down.
Follow the steps as indicated below:
1.
Brew group in the beginning,
lower view.
4. Remove the shower screen
and the gasket completely.
7. Insert the shower screen
into the brew group.
10. Then, move the portafilter
until the shower screen is
locked firmly into the gasket.
The machine can be used again, as described in chapter 6 of the instruction manual.
Translation of the German original user manual
2. Use a flat screwdriver to pry
out the shower screen and
the group gasket.
5. Keep the new spare parts
ready at hand (the rounded
side of the group gasket
with PROFITEC print faced
upwards to the brewing
group).
8. Take the portafilter without
filter.
11. Now you can easily lock the
portafilter into place.
3. The shower screen and the
gasket are now nearly
removed.
6. Clean the group with a
brush. Lock the shower
screen firmly into the
gasket.
9. Clamp the portafilter into the
brew group.
12. The group is ready for use.
ENGLISH
35