Technical Data; Pid-Temperature Control - Profitec PRO 700 User Manual

Hide thumbs Also See for PRO 700:
Table of Contents

Advertisement

Available languages

Available languages

Switches under the drip tray
Please remove the drip try to reach the switches.
Alternatively, the steam boiler switch can also be reached from underneath the chassis
without moving the machine.

3.2 Technical data

Voltages:
Power:
Water tank:
Measurements:
Measurements with portafilter:
Weight:

3.3 PID-Temperature Control

The function of a PID-Temperature Control is to regulate the temperature of both boilers. The temperature
of the boilers are programmable and controlable independently from each other. You have the possibility
to extract coffee at varying temperatures and steaming with different pressure. PID stands for
-integral-
The PID-control shows the temperature of the coffee boiler and the steam boiler alternately. The position
of the period indicates which boiler´s temperature is currently being displayed.
Temperature coffee boiler (t1, here 93°C)
-period in the 1st position
Water tank/Direct water supply switch:
This switch allows you to select the kind of water supply (water tank or direct
water connection).
Pos. 0: water tank
Pos. 1: direct water connection
Steam boiler switch:
This switch allows you to activate or deactivate the steam boiler
Pos. 0: Steam boiler is deactivated.
Pos. 1: Steam boiler is activated.
EU: 230 V
UK: 230 V
New Zealand: 240 V
Australia: 240 V
US: 115 V
Japan: 100 V
1600 W
ca. 2.8 l
B x T x H / 340 mm x 475 mm x 420 mm
B x T x H / 340 mm x 590 mm x 420 mm
31 kg
Temperature steam boiler (t2, here 124°C)
-period in the 3rd position
ENGLISH