Section 8
Problem
1. No product is being
dispensed.
Troubleshooting Guide
Table 8-1
Probable Cause
a. Low on mix. The MIX OUT light is
on.
b. The power switch is in the OFF
position.
c. The beater motor is out on reset.
d. The beater assembly is rotating
counterclockwise.
e. Insufficient mix in the freezing
cylinder.
f. Restriction in the door spout.
g. Machine is unplugged.
h. Circuit breaker is off or the fuse is
blown.
i. The mix probe was not installed
properly or was damaged.
Models 8752, 8756, and 8757
Troubleshooting Guide
Remedy
a. Add mix to the mix tank and press the
AUTO button.
b. Place the power switch in the ON
position and press the AUTO button.
c. Reset the freezer.
d. Contact service technician to correct
rotation to clockwise.
e. Go to problem 2.
f. Remove the draw handle and raise
the draw valve all the way up to
remove restriction. Never put objects
or fingers in door spout.
g. Plug machine into the wall receptacle.
h. Turn the breaker on or replace the
fuse.
i. Check the mix probe installation.