OPERATING PROCEDURES
Sanitizing
1. Prepare a pail of approved 100 ppm sanitizing
solution (examples: 2-1/2 gal. [9.5 L] of Kay-5
2 gal. [7.6 L] of Stera-Sheen
follow the manufacturer's specifications.
2. Place the pail of sanitizing solution inside the mix
cabinet.
3. Brush-clean the mix inlet tube with the long brush
and sanitizing solution.
4. Connect the free end of the flare line to the threaded
fitting on the mix inlet tube.
6
6-10
®
). Use warm water and
Figure 6-36
Figure 6-37
Models 8752, 8756, and 8757
5. Install the pressure line. Attach the quick-disconnect
fitting of the pressure line to the other fitting on the
mix inlet tube just above the flare line and allow the
®
or
other end to hang free.
15059
6. Insert the free end of the suction line and pressure
line into the pail of sanitizing solution.
15060
7. Place the power switch in the ON position.
Figure 6-38
Figure 6-39
Figure 6-40
Operating Procedures
15061
15062