8. Once the stream of mix stops flowing from the prime
plug hole, push down the prime plug. Rinse the prime
plug hole area with water. Remove the pail and
discard the mix and sanitizer.
Figure 6-50
Important! Failure to remove all sanitizing solution
may result in damage to the freezing cylinder.
9. Press the AUTO button. The MIX REF light will come
on to indicate the mix refrigeration system is
operating. The AUTO light will come on to indicate
the main refrigeration system is operating, and the
PUMP light will come on to indicate the air/mix pump
will operate whenever mix is needed in the freezing
cylinder.
Figure 6-51
Repeat step 1 through step 9 for the other side of
the machine on Models 8756 and 8757.
When the machine cycles off, the product will be at
the correct viscosity.
Note: Keep the mix cabinet door closed except
when filling the mix tank and during the cleaning and
sanitizing procedures. Leaving the door open with
the mix refrigeration system on may cause the
evaporator to ice up and impair the mix cabinet
refrigeration.
Operating Procedures

Closing Procedure

To disassemble Models 8752, 8756, and 8757, the
following items will be needed:
Two cleaning and sanitizing pails
Sanitized stainless-steel rerun can with lid
Cleaning brushes (provided with machine)
Cleaner
Single-service towels
Draining Product from the Freezing
Cylinder
1. Press the AUTO and MIX REF buttons to cancel
machine operation.
2. Open the mix cabinet door and remove the mix
storage cover(s), mix probe(s), mix tank cover(s),
and mix tank(s). Empty the mix from the mix tank(s)
into a sanitized stainless-steel rerun can.
3. Place the suction line in an empty pail in the mix
cabinet
4. If local health codes permit the use of rerun, place a
sanitized, NSF-approved stainless-steel rerun
container beneath the door spout. Open the draw
valve and press the WASH and PUMP buttons. Drain
all the mix from the freezing cylinder. When all
product stops flowing from the door spout, close the
draw valve and press the WASH and PUMP buttons
to stop operation. Place the sanitized lid on the rerun
container and place it in the walk-in cooler.
Note: If local health codes do not permit the use of
rerun, the product must be discarded. Follow the
instructions in the previous step, except drain product
into a pail and properly discard the mix.
Repeat steps 3 and 4 for the second freezing cylinder
on Models 8756 and 8757.
FOLLOW YOUR LOCAL HEALTH CODES.