(11) Intermediate presser variable adjustments
Standard Adjustment
Start the Test Mode I10 and press
three times after the completion of origin search. Press
twice
after the completion of origin search. At that time, a value of 3.5 ± 0.2 shall be secured from the amount of rise
of the presser bar (intermediate presser).
±
3.5
0.2mm
D
C
Slit plate
3mm
Sensor
A
B
Start the Test Mode I10 and press the X key after the completion of origin search to withdraw from the Test
Mode I10. Start the Test Mode I10 again (no origin search) and press the "+" key 5 times. Even though the
power supply is turned off after that, the intermediate presser cam
shall not rotate.
After the completion of origin search, press the X key to withdraw from the Test Mode I10. Start the Test Mode
I10 again (no origin search) and press the "–" key 3 times. Even though the power supply is turned off after that,
the intermediate presser cam
shall not rotate.
– 20 –