Datcon DT4200 Operating Instructions Manual page 59

Process indicator
Table of Contents

Advertisement

DT4200
Measuring parameters
Characteristics:
Measuring frequency:
Number of averaged samples:
Limit outputs
Output type:
Current in OFF condition:
Voltage in ON condition:
Load rating:
Refreshing time:
Hysteresis:
Environmental conditions
Operating temperature range:
Storing temperature range:
Electromagnetic compatibility (EMC)
In accordance with EN 61326:2000
Immunity:
Noise emission:
General data
Housing:
Dimensions [mm]:
Panel cut off:
Weight:
Protection:
Mounting position:
Connection cable:
Connection:
Signal, option:
Limit output:
The manufacturer reserves the right to change specifications.
20181113-V0
Linear
15 measurements / second
1; 2; 4; 8; 16; 32 (adjustable)
optically isolated passive switching transistor
I < 0.1mA (at 9 V)
U < 1.2 V (at 10 mA)
30 V, 30 mA max.
same as the display's one
0 - ±999 (the last 3 digits of the display)
0-60 °C (-20 - +60 °C on request)
-25 - +70 °C
-A- criterion
-A- class
panel instrument
96 x 48 x 45 (width x height x depth)
91 x 44 (width x height)
0.15 kg
IP 65 (front)
IP 30 (rear)
Optional, see: figure 4.2.
2
0.25-1.5 mm
6 pole push-in direct connection
4 pole push-in direct connection
59