Installation
8. Mount the cabinet top part back on the cabinet bottom part by first setting the top part
with the two upper straps (16) on the bottom part and then pressing the bottom edge of
the top part carefully against the bottom part, until the two bottom straps (17) latch.
9. For compact systems: Wall mounting is now concluded.
For split system: Replace the cover of the detached operating unit (20) in the front panel
(18) of the indoor unit by the cover of the operating unit opening (21), supplied within the
scope of delivery, to seal the opening (19). Exercise caution as you press the cover, until
the six engagement hooks (22) engage with the front panel.
F
16
U P
17
F Assembly Top/ Bottom Part
16 Top straps
17 Bottom straps
190
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
G
18
19
20
21
22
G Front panel indoor unit
18 Front panel of the indoor unit
19 Operating unit opening
20 Removing cover of the detached operating unit
21 Inserting cover of the operating unit opening
22 Engagement hooks (total 6)
6.9
Starting up the system
Commissioning of the system covers the evacuation of the cooling system (only for split sys-
tems), filling the water system, the concluding inspection of the system installation, test run as
well as system handover and instruction of the end-customer.
6.9.1 Emptying the cooling system and carrying out a pressure test
i
Note
In the case of compact systems, you can skip this section. Continue with section
ing the heating and cooling circuit, p.
CAUTION
Danger of injury due to unprofessional handling of coolants
Unprofessional handling of coolants leads to various dangers of injury such as freezing, fire and
the danger of explosions and the danger of injury occurring.
► Working with the coolant must be done by a trained skilled person or an authorised
dealer with refrigerant certification.
► Observe all the Safety Notices in force for the respective coolant (R410A or R407C).
CAUTION
Danger of the devices being damaged by incorrect coolant
Using coolants or coolant mixtures not indicated in this manual or the respective operating
instructions can lead to damage to devices and safety risks.
► Only use coolant Type R410A for the Aquarea LT and T-CAP series and only Type
R407C coolant for the Aquarea HT series.
► Do not mix the prescribed coolant with coolants of another type or replace it with a
coolant of another type.
Danger of faults in the cooling circuit due to humidity and external gases
To avoid faults in the cooling circuit due to penetrating humidity or external gases, the system
must be evacuated before commissioning in all cases.
► The system must be evacuated in all cases before commissioning and a pressure test
be conducted.
► If the length of the coolant pipelines is greater than the pre-filled connection distance
of the device
(→ 4 Technical data (split systems), p.
(compact systems), p.
50), the indicated quantity of additional coolant must be
added.
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Installation
→ 6.9.2.2 Fill-
195.
→ 4.6.3.3 Technical data
16,
191