Product Description
4.8.2 Aquarea Tank
CAUTION
Danger of damage to heating system due to corrosion in buffer tank due to inadequate
water quality
When using Aquarea tanks, take the following into consideration, in addition to the above-men-
tioned requirements for water quality.
► Ensure that the European and national requirements regarding heating water quality
are met.
► In particular, ensure that the following values are not exceeded:
Chlorine 100 mg/l, calcium 100 mg/l, iron / manganese 0.5 mg/l.
4.8.2.1 Product features
The Aquarea tank is a high-performance, and modern tank, which was developed especially for
the requirements of the Aquarea heat pumps. The hot water tank with a volume of 185 litres is
located in the upper area of the tank and a smaller buffer tank with a volume of 80 litres in the
lower area. This makes the Aquarea tank ideal for domestic water heating and heating usable in
single family houses. The complete model ensures very low standby losses and quick assembly
due to the pre-installed assembly groups such as 3-way valve or E-Heating element hot water
tank (with safety thermostat and fault reporting contact)
The use of the Aquarea tank helps implement multiple functions efficiently and easily, such as:
● Domestic water heating
● Hydraulic disconnection of heat pumps and heat consumer circuit
● Ensuring minimum volume in the heating system
● Buffer function for optimum operation of the Aquarea heat pumps
Note the respective installation instructions enclosed when installing the Aquarea tank. Other
accessories are also mentioned in it, which are needed for the installation of the hot water-/
buffer tank combination in the heating system and must be provided by the client.
74
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
4.8.2.2 Components, connections and dimensions
A
Internal view from front
18
1
2
17
16
15
14
13
12
1 Hot water outlet
2 Protective anode
3 Domestic cold water connection
4 Heating circuit inflow
5 Heating circuit return (only seen in plan view)
6 Connection box
7 Connection terminal block (3-way valve, heating
circuit pump, E-heating element hot water tank and
temperature sensor)
8 E-heating element hot water tank (3 kW)
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
B
Plan view
3 4
1
2
3
5
18
5
17
4
16
6
7
8
9
10
11
9 Overheat protection
1 0 Heating circuit pump (High efficiency pump)
11 Draining valve of the buffer tank
12 Bleeder valve
13 Draining valve of the hot water tank
14 Tank insulation (Polyurethane, 50 mm)
15 3-way-valve
16 3 x cable gland
1 7 Inflow from the heat pump
18 Return to the heat pump
75