Panasonic Aquarea B1 Planning And Installation Manual page 28

Air-to-water heat pumps split systems and compact systems
Table of Contents

Advertisement

Product Description
4.6.3.3 Technical Data
Compact system / LT series / H generation
LT series
Single-phase (230 V / 50 Hz), Heating and Cooling
Compact device
WH-MDC05H3E5
Model
B8
Heating capacity at +7 °C (A7/W35)
kW
5.00
COP at +7 °C (A7/W35)
5.08
Heating capacity at +2 °C (A2/W35)
kW
4.80
COP at +2 °C (A2/W35)
3.75
Heating capacity at -7 °C (A–7/W35)
kW
4.50
COP at -7 °C (A–7/W35)
2.98
Energy efficiency class
at 35 / 55 °C
1
i * / i
Cooling capacity at 35 °C (A35/W7)
kW
4.50
EER (energy efficiency ratio) at 35 °C (A35/W7)
3.33
Sound pressure level
Heating / Cooling
dB(A)
49 / 47
Sound power (A7/W55)
Heating / Cooling
dB(A)
65 / 65
Dimensions
H x L x W
mm
865 x 1,283 x 320
Weight
kg
107
Water-side connection
mm
28
High efficiency pump
Rotation speed stages
Variable
Power consumption (min./ max.) W
34 / 96
Water flow rate (A7/W35)
l/min
14.3
Power of E-heating element
kW
3
Power consumption
Heating / Cooling
kW
0.985 / 1.35
Operating and start up current Heating / Cooling
A
4.5 / 6.1
Max. power consumption on network connection 1 / 2
A
19.5 / 13.0
Recommended fuse for network connection 1 / 2
A
30 / 15
Recommended cable cross section for network connection 1 / 2 mm²
3 x 4.0 or 6.0 / 3 x 4.0
Pre-filled refrigerant (R410A) / CO
-equivalent
kg / t CO
-Equ.
1.42 / –
2
2
Operating range
Outside temperature (H / K)
°C
-20 to 35 / 16 to 43
Water outlet temperature (H / K) °C
20 to 55 / 5 to 20
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efficiency classes is based on the official ErP specifications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been
in force since 26. September 2015. The efficiency classes marked with an asterisk (*) correspond to the new A+++ class to be introduced starting in September 2019. Other ErP relevant
information is included in the respective product data sheets.
Authorised Service Partners or installation companies can activate the cooling function via a special setting.
1 Energy efficiency class scale from A++ to G.
50
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
WH-MDC07H3E5
WH-MDC09H3E5
B8
B8
7.00
9.00
4.46
4.15
5.00
7.45
3.45
3.14
5.15
7.70
2.68
2.12
i * / i
i * / i
5.50
7.00
2.74
2.44
49 / 47
51 / 49
65 / 65
69 / 67
865 x 1,283 x 320
865 x 1,283 x 320
112
112
28
28
Variable
Variable
36 / 100
39 / 108
17.2
25.8
3
3
1.34 / 2.01
2.17 / 2.87
6.1 / 9.3
9.9 / 13.0
20.5 / 13.0
22.9 / 13.0
30 / 15
30 / 16
3 x 4.0 or 6.0 / 3 x 4.0
3 x 4.0 or 6.0 / 3 x 4.0
1.42 / –
1.42 / –
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
20 to 55 / 5 to 20
20 to 55 / 5 to 20
Compact system / T-CAP model series / H Generation
T-CAP model series
Single-phase (230 V / 50 Hz), Heating and Cooling
Compact device
WH-MXC09H3E5
Model
B9
Heating capacity at +7 °C (A7/W35)
kW
9.00
COP at +7 °C (A7/W35)
4.84
Heating capacity at +2 °C (A2/W35)
kW
9.00
COP at +2 °C (A2/W35)
3.59
Heating capacity at -7 °C (A–7/W35)
kW
9.00
COP at -7 °C (A–7/W35)
2.85
Energy efficiency class
at 35 / 55 °C
1
i / i
Cooling capacity at 35 °C (A35/W7)
kW
7.00
EER (energy efficiency ratio) at 35 °C (A35/W7)
3.17
Sound pressure level
Heating / Cooling
dB(A)
51 / 49
Sound power (A7/W55)
Heating / Cooling
dB(A)
68 / 67
Dimensions
H x L x W
mm
1,410 x 1,283 x 320
Weight
kg
148
Water-side connection
mm
28
High efficiency pump
Rotation speed stages
Variable
Power consumption (min./ max.) W
32 / 102
Water flow rate (A7/W35)
l/min
25.8
Power of E-heating element
kW
3
Power consumption
Heating / Cooling
kW
1.86 / 2.21
Operating and start up current Heating / Cooling
A
8.6 / 10.2
Max. power consumption on network connection 1 / 2
A
25.0 / 13.0
Recommended fuse for network connection 1 / 2
A
30 / 30
Recommended cable cross section for network connection 1 / 2 mm²
3 x 4.0 or 6.0 / 3 x 4.0
Pre-filled refrigerant (R410A) / CO
-equivalent
kg / t CO
-Equ. 2.3 / 4.802
2
2
Operating range
Outside temperature (H / K)
°C
-20 to 35 / 16 to 43
Water outlet temperature (H / K) °C
25 to 55 / 5 to 20
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efficiency classes is based on the official ErP specifications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been
in force since 26. September 2015. The efficiency classes marked with an asterisk (*) correspond to the new A+++ class to be introduced starting in September 2019. Other ErP relevant
information is included in the respective product data sheets.
Authorised Service Partners or installation companies can activate the cooling function via a special setting.
1 Energy efficiency class scale from A++ to G.
All data is provisional.
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Product Description
Three-phase (400 V / 50 Hz), heating and cooling
WH-MXC12H6E5
WH-MXC09H3E8
WH-MXC12H9E8
WH-MXC16H9E8
B9
B9
B9
B9
12.00
9.00
12.00
16.00
4.74
4.84
4.74
4.28
12.00
9.00
12.00
16.00
3.44
3.59
3.44
3.10
12.00
9.00
12.00
16.00
2.72
2.85
2.72
2.49
i / i
i * / i
i * / i
i * / i
10.00
7.00
10.00
12.20
2.81
3.17
2.81
2.56
52 / 50
51 / 49
52 / 50
55 / 54
69 / 68
68 / 67
69 / 68
72 / 72
1,410 x 1,283 x 320
1,410 x 1,283 x 320
1,410 x 1,283 x 320
1,410 x 1,283 x 320
148
155
155
168
28
28
28
28
Variable
Variable
Variable
Variable
34 / 110
32 / 102
34 / 110
38 / 120
34.4
25.8
34.4
45,9
6
3
9
9
2.53 / 3.56
1.86 / 2.21
2.53 3.56
3.74 / 4.76
11.7 / 16.5
2.8 / 3.4
3.8 / 5.3
5.7 / 7.2
29.0 / 26.0
14.7 / 13.0
11.9 / 13.0
15.5 / 13.0
30 / 30
16 / 16
16 / 16
16 / 16
3 x 4.0 or 6.0 / 3 x 4.0
5 x 1.5 / 3 x 1.5
5 x 1.5 / 5 x 1.5
5 x 1.5 / 5 x 1.5
2.3 / 4.802
2.3 / 4.802
2.3 / 4.802
2.35 / 4.907
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
25 to 55 / 5 to 20
25 to 55 / 5 to 20
25 to 55 / 5 to 20
25 to 55 / 5 to 20