Panasonic Aquarea B1 Planning And Installation Manual page 58

Air-to-water heat pumps split systems and compact systems
Table of Contents

Advertisement

Planning
Models
Mains connection 1
Phases
Max. current
consumption (A)
WH-SDC12H9E8 +
3
8.8
WH-UD12HE8
WH-SDC16H9E8 +
3
9.9
WH-UD16HE8
WH-SXC12H9E8 +
3
11.9
WH-UX12HE8
WH-SXC16H9E8 +
3
15.5
WH-UX16HE8
WH-SQC12H9E8 +
3
11.9
WH-UQ12HE8
WH-SQC16H9E8 +
3
15.5
WH-UQ16HE8
WH-SHF12F9E8 +
3
10.8
WH-UH12FE8
For model WH-SHF09F3E8
FI protection switch and mains connections
For model WH-SHF09F3E8
L
L
L
N
A1
A2
A3
FI protection
switch
L
L
L
N
POWER SUPPLY 2
A1
A2
A3
For model WH-SHF12F9E8
L B1
L B2
L B3
N
For model WH-SHF12F9E8
Mains connections
LN
11
L
L
L
N
B1
B2
B3
L
L
L
N
B1
B2
B3
Mains connection 2
Connection conditions
For hydro-modules of the F generation:
● For the connection to the electricity supply, use an approved power cord with poly-
chloroprene material, symbol 60245 IEC 57 or higher, for mains connection.
● An approved flexible cable with polychloroprene material, symbol 60245 IEC 57 or
higher is to be used as the connecting cable between indoor and outdoor units
POWER SUPPLY 2
POWER SUPPLY 1
L B1
L B2
L B3
N
L A1
L A2
L A3
N
LN
N
L
11
45
110
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
A
Mains connection 2
Max. power
Phases
Max. current
consumption (kW)
consumption (A)
5.85
3
13.0
6.59
3
13.0
7.91
3
13.0
10.27
3
13.0
7.91
3
13.0
10.27
3
13.0
7.07
3
13.0
POWER SUPPLY 2
POWER SUPPLY 1
Indoor unit /outdoor unit connection
1
2
3
4
5
Terminals on outdoor unit
1
1
2
3
4
5
1
2
3
4
5
L
N
Terminals on indoor unit
2
L B1
L B2
L B3
N
L A1
L A2
L A3
N
L
L
L
N
1
2
3
4
5
L
N
A1
A2
A3
L
N
Terminals on disconnector of the mains connection
POWER SUPPLY 1
3
L
L
L
N
L
N
N
L
A1
LN
A2
A3
11
Terminal block strip
Indoor unit / outdoor unit
1
2
3
L A1
L A2
L A3
N
1
2
3
4
5
N
L
1
2
3
4
N
L
22
2
L
L
L
N
1
2
3
4
5
A1
A2
A3
L
L
L
N
L
L
L
N
1
2
3
4
B1
B2
B3
A1
A2
A3
L
L
L
N
3
A1
A2
A3
L
L
L
N
L
L
L
N
Connection of indoor unit
B1
B2
B3
A1
A2
A3
Mains connection 1
and outdoor unit
A
A
POWER SUPPLY 2
POWER SUPPLY 1
N
L
22
L B1
L B2
L B3
N
L A1
L A2
L A3
N
LN
11
N
L
N
L
22
45
Max. power
consumption (kW)
9.0
9.0
9.0
9.0
9.0
9.0
9.0
N
L
22
4
5
5
1
5
2
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
For the hydro-module WH-SHF09F3E5 and WH-SHF12F6E5.
● Mains supply 1 of this device fulfils EN/IEC 61000-3-12, provided that the short-cir-
cuit power S
at the transfer point of the energy provider to the operator is greater
k
than or equal to 1100 kW. The installer or operator of the device is, therefore,
responsible for ensuring, in case a consultation with the EVU is needed, that the
device is only connected, if the short-circuit power S
1100 kW.
● Mains supply 1 of the device is to be connected to a suitable voltage source, which
has a current rating ≥100 A per phase. Connect to the EVU to ensure that the cur-
rent rating at the transfer point is sufficient for the device.
● Mains supply 2 of this device fulfils EN/ IEC 61000-3-12.
● Mains supply 2 of the device is to be connected to a suitable voltage source, with
a maximum system impedance of Z
= 0.244 Ω at the transfer point. Connect to
max
the EVU to ensure that the mains supply 2 is only connected to a grid with the max-
imum of this impedance.
For the hydro-module WH-SHF09F3E8:
● Mains supply 1 of this device fulfils EN/ IEC 61000-3-12.
● Mains supply 2 of this device fulfils EN/ IEC 61000-3-12.
For the hydro-module WH-SHF12F9E8
● Mains supply 1 of this device fulfils EN/ IEC 61000-3-12.
● Mains supply 2 of this device fulfils EN/ IEC 61000-3-12.
● Mains supply 2 of the device is to be connected to a suitable voltage source, with
a maximum system impedance of Z
= 0.449 Ω at the transfer point. Connect to
max
the EVU to ensure that the mains supply 2 is only connected to a grid with the max-
imum of this impedance.
For hydro-modules of the H generation:
● For the connection to the electricity supply, use an approved power cord with poly-
chloroprene material, symbol 60245 IEC 57 or higher, for mains connection.
● An approved flexible cable with polychloroprene material, symbol 60245 IEC 57 or
higher is to be used as the connecting cable between indoor and outdoor units
For the hydro-modules WH-SDC03H3E5-1, WH-SDC05H3E5-1, WH-SDC07H3E5-1 and
WH-SDC09H3E5-1, WH-SDC09H3E8, WH-SXC09H3E8, WH-SQC09H3E8:
● Mains supply 1 of this device fulfils EN/ IEC 61000-3-2.
● Mains supply 1 of this device fulfils EN/ IEC 61000-3-3 and can be connected to
the current supply grid.
● Mains supply 2 of this device fulfils EN/ IEC 61000-3-2.
● The mains supply 2 of this device fulfills IEC/EN 61000-3-11 and is to be connected
to a suitable voltage source, whose maximum allowed system impedance at the
interface is Z
= 0.426 Ω. Connect to the EVU to ensure that the mains supply 2
max
is only connected to a grid with the maximum of this impedance.
Planning
is greater than or equal to
k
111

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents