Appendix
Menus
For installers
Menu
5.13
Fault alarm output
5.14
Power control
5.15
SG ready
5.16
Ext. switch for OU
5.17
Liquid
Selection as to whether water
or glycol is being used as the
heating medium.
5.18
Heating/cooling scheme
5.19
Man. E-heating
For switching on the
emergency heating mode
manually (standard) or
automatically.
6 Installer set-up Operational setting
Setting the four operating
modes.
*1 The system is preset for operation without a cooling function. The cooling function can be activated by an authorised installer or service
partner.
*2 This display only appears if the cooling function is activated, i.e. if the cooling mode is available.
214
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Standard setting
Setting options /Display
No
No
No
Yes
Boost
(Stages 1 and 2)
120 %
of buffer tank and
domestic hot water tank
(in %)
No
Water
No
Man.
4 operating modes
Heating / cooling *
*
/ Auto / Hot water tank
1,
2
Menu
Installer set-up Operational setting
6.1
Heating
Setting of different
temperatures for the heating
mode.
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Standard setting
Setting options /Display
Water temp. set-point heating /
Summer shutdown /
T for heating mode /
Bivalence temp. of E-heating element
Water temp. set-point heating
Setting of whether the
supply temperature is to
Heating
be calculated according
to heating levels or to be
definitively set.
Water temperature set-point for heating Heating curve
Entry of 4 temperature
X axis:
values.
-5 °C, 15 °C
(2 on the horizontal X
Y axis:
axis, 2 on the vertical
55 °C, 35 °C
Y axis).
• Temperature range for the X-axis: -15 °C to 15 °C, Y-axis: see below.
• Temperature range for the Y-axis depends on the model:
1. Model WH-SDC: 20°C to 55°C
2. Model WH-SHF and E-heating element are activated: 25°C to 65°C
3. Model WH-SHF and E-heating element are not activated: 35°C to 65°C
4. Model WH-SXC/SQC: 20°C to 60°C
• If a second heating circuit is present, the 4 temperature values must also be given for
heatC 2.
• "HC 1" and "HC 2" are not shown in the display if the system only has one heating
circuit.
Water temperature set-point for heating Fixed value
Inputting a fixed flow
35 °C
temperature
• The following input ranges are available:
1. Model WH-SDC: 20°C to 55°C
2. Model WH-SHF and E-heating element are activated: 25°C to 65°C
3. Model WH-SHF and E-heating element are not activated: 35°C to 65°C
4. Model WH-SXC/SQC: 20°C to 60°C
Summer shutdown
Outside temperature
at which the heating is
24 °C
switched off (summer
mode)
Appendix