Panasonic Aquarea B1 Planning And Installation Manual page 24

Air-to-water heat pumps split systems and compact systems
Table of Contents

Advertisement

Product Description
Split systems with hydro-module / LT series / H Generation
LT series
Single-phase (230 V / 50 Hz), Heating and Cooling
Hydro-module
WH-SDC03H3E5-1
Outdoor unit
WH-UD03HE5-1
Set (hydro-module + outdoor unit)
KIT-WC03H3E5-1
Model
B4
Heating capacity at +7 °C (A7/W35)
kW
3.20
COP at +7 °C (A7/W35)
5.00
Heating capacity at +2 °C (A2/W35)
kW
3.20
COP at +2 °C (A2/W35)
3.56
Heating capacity at -7 °C (A–7/W35)
kW
3.20
COP at -7 °C (A–7/W35)
2.69
Cooling capacity at 35 °C (A35/W7)
kW
3.20
EER at 35 °C (A35/W7)
3.08
Energy efficiency class
at 35 / 55 °C
1
i*/ i
Composite energy efficiency class
at 35 / 55 °C
2
j / i
Hydro-module
Sound pressure level
Heating / Cooling
dB(A)
28 / 28
Dimensions
H x L x W
mm
892 x 500 x 340
Weight
kg
44
Water-side connection
mm
28
Rotation speed stages
Variable
High efficiency pump
Power consumption (min./ max.) W
30 / 100
Water flow rate (A7/W35)
l/min
9.2
Power of E-heating element
kW
3
Power consumption
Heating / Cooling
kW
0.64 / 1.04
Operating and start up current Heating / Cooling
A
3.0 / 4.8
Max. power consumption on network connection 1 / 2
A
11.0 / 13.0
Recommended fuse for network connection 1 / 2
A
15 / 30
Recommended cable cross section for network connection 1 / 2 mm²
3 x 1.5 / 3 x 1.5
Outdoor unit
Sound pressure level
Heating / Cooling
dB(A)
47 / 47
Dimensions
H x L x W
mm
622 x 824 x 298
Weight
kg
39
Fluid line
mm (inches)
6.35 (1/4)
Line diameter
Gas line
mm (inches)
12.7 (1/2)
Pre-filled refrigerant (R410A) / CO
-equivalent
kg / t CO
-Equ.
1.20 / 2.506
2
2
Connection distance
m
3 – 15
Nominal connection distance
m
7
Pre-filled connection distance
m
10
Additional coolant fill-up quantity (R410A)
g/m
20
Max. height difference IU/OU
m
5
Operating range
Outside temperature (H / K)
°C
-20 to 35 / 16 to 43
Water outlet temperature (H / K) °C
20 to 55 / 5 to 20
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efficiency classes is based on the official ErP specifications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been
in force since 26. September 2015. The efficiency classes marked with an asterisk (*) correspond to the new A+++ class to be introduced starting in September 2019. Other ErP relevant
information is included in the respective product data sheets.
Authorised Service Partners or installation companies can activate the cooling function via a special setting.
1 Energy efficiency class scale from A++ to G.
2 Energy efficiency class including controller. Energy efficiency class scale from A+++ to D.
42
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
WH-SDC05H3E5-1
WH-SDC07H3E5-1
WH-SDC09H3E5-1
WH-SDC12H6E5
WH-UD05HE5-1
WH-UD07HE5-1
WH-UD09HE5-1
WH-UD12HE5
KIT-WC05H3E5-1
KIT-WC07H3E5-1
KIT-WC09H3E5-1
KIT-WC12H6E5
B4
B5
B5
B6
5.00
7.00
9.00
12.0
4.63
4.46
4.13
4.74
4.20
6.55
6.70
11.40
3.11
3.34
3.13
3.44
4.20
5.15
5.90
10.00
2.59
2.68
2.52
2.73
4.50
6.00
7.00
10.00
2.69
2.63
2.43
2.81
i / i
i*/ i
i*/ i
i*/ i
j / i
j / i
j / i
j / i
28 / 28
30 / 30
30 / 30
33 / 33
892 x 500 x 340
892 x 500 x 340
892 x 500 x 340
892 x 502 x 353
44
44
44
45
28
28
28
28
Variable
Variable
Variable
Variable
33 / 106
34 / 114
40 / 120
34 / 110
14.3
20.1
25.8
34.4
3
3
3
6
1.08 / 1.67
1.57 / 2.28
2.18 / 2.88
2.53 / 3.56
5.0 / 7.6
7.2 / 10.3
10.0 / 13.0
11.5 / 16.0
12.0 / 13.0
21.0 / 13.0
22.9 / 13.0
24.0 / 26.0
15 / 30
15 / 30
15 / 30
30 / 30
3 x 1.5 / 3 x 1.5
3 x 1.5 / 3 x 1.5
3 x 1.5 / 3 x 1.5
3 x 4.0 or 6.0 / 3 x 4.0
48 / 48
50 / 48
51 / 50
52 / 50
622 x 824 x 298
795 x 900 x 320
795 x 900 x 320
1,340 x 900 x 320
39
66
66
101
6.35 (1/4)
6.35 (1/4)
6.35 (1/4)
9.52 (3/8)
12.7 (1/2)
15.88 (5/8)
15.88 (5/8)
15.88 (5/8)
1.20 / 2.506
1.45 / 3.028
1.45 / 3.028
2.55 / 5.324
3 – 15
3 – 30
3 – 30
3 – 30
7
7
7
7
10
10
10
10
20
30
30
50
5
20
20
20
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
20 to 55 / 5 to 20
25 to 55 / 5 to 20
25 to 55 / 5 to 20
25 to 55 / 5 to 20
Split Systems with Hydro-Module / LT Series / H Generation (contd.)
LT series
WH-SDC16H6E5
Hydro-module
WH-UD16HE5
Outdoor unit
KIT-WC16H6E5
Set (hydro-module + outdoor unit)
B6
Model
16.00
Heating capacity at +7 °C (A7/W35)
4.28
COP at +7 °C (A7/W35)
13.00
Heating capacity at +2 °C (A2/W35)
3.28
COP at +2 °C (A2/W35)
11.40
Heating capacity at -7 °C (A–7/W35)
2.68
COP at -7 °C (A–7/W35)
12.20
Cooling capacity at 35 °C (A35/W7)
2.56
EER at 35 °C (A35/W7)
Energy efficiency class
at 35 / 55 °C
i / i
1
Hydro-module
j / i
Sound pressure level
Heating / Cooling
33 / 33
Dimensions
H x L x W
892 x 502 x 353
Weight
46
Water-side connection
28
Rotation speed stages
High efficiency pump
Variable
Power consumption (min./ max.) W
30 / 105
Water flow rate (A7/W35)
45,9
Power of E-heating element
6
Power consumption
Heating / Cooling
3.07 / 4.36
Operating and start up current Heating / Cooling
13.9 / 19.5
Max. power consumption on network connection 1 / 2
25.0 / 26.0
Recommended fuse for network connection 1 / 2
30 / 30
Recommended cable cross section for network connection 1 / 2 mm²
3 x 4.0 or 6.0 / 3 x 4.0
Outdoor unit
Sound pressure level
Heating / Cooling
55 / 54
Dimensions
H x L x W
1,340 x 900 x 320
Weight
101
Fluid line
Line diameter
9.52 (3/8)
Gas line
15.88 (5/8)
Pre-filled refrigerant (R410A) / CO
-equivalent
2
2.55 / 5.324
Connection distance
3 – 30
Nominal connection distance
7
Pre-filled connection distance
10
Additional coolant fill-up quantity (R410A)
50
Max. height difference IU/OU
20
Operating range
Outside temperature (H / K)
-20 to 35 / 16 to 43
Water outlet temperature (H / K) °C
25 to 55 / 5 to 20
The COP details relate to 230 V in conformance with the EC Directives 2003/32/EC. Power details in conformance with EN 14511.
The information about the energy efficiency classes is based on the official ErP specifications (EU Ordinance No. 811/2013, EN 14511 and EN 14825) for heat pumps, which have been
in force since 26. September 2015. The efficiency classes marked with an asterisk (*) correspond to the new A+++ class to be introduced starting in September 2019. Other ErP relevant
information is included in the respective product data sheets.
Authorised Service Partners or installation companies can activate the cooling function via a special setting.
1 Energy efficiency class scale from A++ to G.
Aquarea air-to-water heat pumps - Planning and installation manual - 01/2018
Three-phase (400 V / 50 Hz), heating and cooling
WH-SDC09H3E8
WH-SDC12H9E8
WH-UD09HE8
WH-UD12HE8
KIT-WC09H3E8
KIT-WC12H9E8
B6
B6
kW
9.00
12.00
4.84
4.14
kW
9.00
11.40
3.59
3.44
kW
9.00
10.00
2.85
2.73
kW
7.00
10.00
3.17
2.81
i / i
i / i
dB(A)
28 / 28
28 / 28
mm
892 x 500 x 340
892 x 500 x 340
kg
44
44
mm
28
28
Variable
Variable
32 / 102
34 / 110
l/min
25.8
34.4
kW
3
3
kW
1.86 / 2.21
2.53 / 3.51
A
2.8 / 3.4
3.8 / 5.3
A
11.8 / 13.0
8.8 / 13.0
A
15 / 30
15 / 30
3 x 1.5 / 3 x 1.5
3 x 1.5 / 3 x 1.5
dB(A)
51 / 49
52 / 50
mm
1,340 x 900 x 320
1,340 x 900 x 320
kg
108
108
mm (inches)
9.52 (3/8)
9.52 (3/8)
mm (inches)
15.88 (5/8)
15.88 (5/8)
kg / t CO
-Equ.
2.55 / 5.324
2.55 / 5.324
2
m
3 – 30
3 – 30
m
7
7
m
10
10
g/m
50
50
m
20
20
°C
-20 to 35 / 16 to 43
-20 to 35 / 16 to 43
25 to 55 / 5 to 20
25 to 55 / 5 to 20
Product Description
WH-SDC16H9E8
WH-UD16HE8
KIT-WC16H9E8
B6
16.00
4.28
13.00
3.28
11.40
2.68
12.20
2.56
i / i
28 / 28
892 x 500 x 340
44
28
Variable
30 / 105
45,9
3
3.07 / 4.36
4.7 / 6.5
9.4 / 13.0
15 / 30
3 x 1.5 / 3 x 1.5
55 / 54
1,340 x 900 x 320
108
9.52 (3/8)
15.88 (5/8)
2.55 / 5.324
3 – 30
7
10
50
20
-20 to 35 / 16 to 43
25 to 55 / 5 to 20
43

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents