A.2 - Removing the device from the Z-Wave network
A
NOTES AND WARNINGS
• During removal procedure all information about the Z-Wave gateway and user configuration will be deleted.
• Positions of limit switches will not reset after removing from the Z-Wave network.
• If the removing process is unsuccessful, repeat the procedure again.
1
2
ON
Connect the electrical pow-
Set the Z-Wave gateway into
er supply to the motor.
removing mode (see the Z-
Wave gateway's manual).
A.3 - TOTAL deletion of memory (factory reset)
A
NOTES AND WARNINGS
• Reset procedure allows to restore the device back to its factory settings, which means all information about the Z-Wave gateway and user configuration will be deleted.
• Resetting the device is not the recommended way of removing the device from the Z-Wave network. Use reset procedure only if the primary gateway is missing or
inoperable. Certain device removal can be achieved by the procedure of removing (A.2).
1
= 20 sec
On the motor head: Hold down either of
the two buttons;
A.4 - Programming of the UP ("0") and DOWN ("1") limit switches
A
NOTES AND WARNINGS
• Both limit switches must be programmed before controlling the motor to move to a specific position.
• Positions of limit switches are set using configuration parameters. The way of adjusting them depends on the Z-Wave gateway you are using, consult the gateway
manual for more information.
• Positions of limit switches can be programmed only when the motor is stopped.
• Positions of limit switches will reset after performing factory reset, but will not reset after removal from the Z-Wave network.
A.4.1 - To program the UP limit switch ("0")
1
Command
an UP
movement
In the Z-Wave gateway interface: set
the position to 100% (Switch Multilevel
Set command)
A.4.2 - To program the DOWN limit switch ("1")
1
Command
an DOWN
movement
In the Z-Wave gateway interface: set
the position to 0% (Switch Multilevel Set
command)
3
(x 3)
On the motor head: press and release
either of the two buttons (3 times);
2
release it after 5 seconds;
2
" 0 "
" 0 "
As soon as the awning reaches
position "0" (UP limit switch)
2
" 1 "
" 1
As soon as the awning reach-
es position "1" (DOWN limit
switch)
5
...
Wait ...
3
the green led starts flashing slowly (it turns
off when the procedure is completed).
3
Command
Save UP limit switch
an STOP
position
movement
stop the movement
Set configuration param-
(Switch Multilevel
eter 33 to value 1.
Stop command).
3
Command
Save DOWN limit
an STOP
switch position
movement
stop the movement
Set configuration param-
(Switch Multilevel
eter 34 to value 1.
Stop command).
end
If removing is successful: the light
starts flashing green slowly;
If removing is unsuccessful: the light
turns solid red for 3 seconds.
end
end