6
Z-WAVE SPECIFICATION
The device is a Security Enabled Z-Wave Plus™ product and a
Security Enabled Z-Wave Controller must be used in order to
fully utilize the product.
The device may be used with all devices certified with the Z-Wave Plus
certificate and should be compatible with such devices produced by
other manufacturers.
The device works as a Z-Wave signal repeater (all non-battery operated
devices within the network will act as repeaters to increase reliability
of the network).
Generic Device Type: GENERIC_TYPE_SWITCH_MULTILEVEL
Specific Device Type: SPECIFIC_TYPE_CLASS_C_MOTOR_CON-
TROL
TABLE E – Supported Command Classes
Command Class
ZWAVEPLUS_INFO
SWITCH_MULTILEVEL
ASSOCIATION
CONFIGURATION
SCENE_ACTIVATION
SCENE_ACTUATOR_CONF
NOTIFICATION
APPLICATION_STATUS
ASSOCIATION_GRP_INFO
TRANSPORT_SERVICE
VERSION
MANUFACTURER_SPECIFIC
DEVICE_RESET_LOCALLY
POWERLEVEL
SECURITY
SECURITY_2
SUPERVISION
FIRMWARE_UPDATE_MD
TABLE F – Association Command Class
Group
Group Name
Profile
1
Lifeline
General:
Lifeline
2
Retransmit
General:
NA
3
Configuration
General:
NA
TABLE G – Multilevel Switch Command Class / Basic CC Mapping
Basic Command
Basic Set (Value)
Basic Report (Current Value, Duration)
Version
Secure
2
4
YES
2
YES
2
YES
1
YES
1
YES
8
YES
1
1
YES
2
2
YES
2
YES
1
YES
1
YES
1
1
1
4
YES
Max.
Description
Nodes
Supported
5
Reports the device status to
the Z-Wave controller.
5
Retransmits Basic Set, Mul-
tilevel Switch Set, Multilevel
Switch Start Level Change,
Multilevel Switch Stop Level
Change or Scene Activate
Set to the associated
nodes.
5
Retransmits configura-
tion for parameters 39..43
(Configuration Bulk Set or
Configuration Set) to the
associated nodes.
Mapped Command
Multilevel Switch Set (Value)
Multilevel Switch Report (Value, Dura-
tion)
TABLE H – Multilevel Switch Command Class SET
Value
Duration
Level
0x00
Ignore
0%
0x01..0x63
Ignore
Lowest non zero level ..
100%
0x64..0xFE
Ignore
reserved
0xFF
Ignore
Last non zero level
TABLE I – Multilevel Switch Command Class Report
The Duration in Multilevel Switch Report advertises the time needed to reach the
Target Value at the actual transition rate.
TABLE J – Notification Command Class
Notification
Event
Type
Heat Alarm
Overheat detected
(0x04)
(0x02)
Power Manage-
Over-current detected
ment (0x08)
(0x06)
System (0x09)
System hardware
failure (manufacturer
proprietary failure
code provided) [0x03]
TABLE K – Configuration Command Class
33. Configuration of upper limit switch
Description
This parameter is used to save upper limit of the motor as the
actual position of the motor. Upper limit must be set before
controlling the motor to move to a specific position and only
when the motor stops.
Upper limit will not reset when device is removed from the
network.
Parameter size
1B
Default value
0
Available
0 – reset upper limit/upper limit not set
values
1 – set upper limit/upper limit set
34. Configuration of lower limit switch
Description
This parameter is used to save upper limit of the motor as the
actual position of the motor. Upper limit must be set before
controlling the motor to move to a specific position and only
when the motor stops.
Upper limit will not reset when device is removed from the
network.
Parameter size
1B
Default value
0
Available
0 – reset lower limit/lower limit not set
values
1 – set upper limit/upper limit set
39. Default motor cruise speed
Description
This parameter is used to configure the motor default cruise
speed.
Parameter size
4B
Default value
32
Available
16 ... 48 – rotations per minute
values
41. Acceleration configuration
Description
This parameter is used to configure how many rotations the
motor will accelerate to default cruise speed.
Parameter size
4B
Default value
0
Available
0 ... 30 – 0.1... 3 rotations
values
Description
Close
Set level .. Fully open
Set last non zero
level
Event/State
Description
Parameter
Curtain motor is
overheat.
Curtain motor is
over-current.
0x01
Overtorque
0x02
Obstacle
0x03
Under voltage
0x04
Unresolvable
0x05
UART communi-
cation error
English – 12