5
Installation
5.5
Mounting the Applicator
!
Attention!
Disconnect the printer from the power supply before mounting/demounting the applicator!
Ensure the printer is in a stable position
Only when the applicator is securely mounted on the printer connect the compressed air.
Figure 11 Mounting the applicator to the printer
5.6
Releasing the Transportation Lock
Figure 12 Stopper/transportation lock as transportation safety
Before the applicators are delivered, a stopper/transportation lock (2) is mounted on the rod (1). With this stopper (2)
the labelling position for the operation mode "blow on" can be adjusted. In transit the same stopper is in the transport
safety position, ensuring that the movement of the tamp is kept to a minimum. For longer transit times a stopper with
a cushion (4) further reduces the impact energy.
Releasing the transportation lock
1. Loosen the screw (3) of the stopper (2).
2. Move the stopper (2) to the top like described in chapter 6.5.
3. Tighten the screw (3) to fix the stopper (2) in place.
1
1. Lower the applicator hinges (1) into the
printers hinges (2) effectively attaching the two
components.
2
2. Pull out the SUB-D 15 plug (6) a little from the
applicator to insert in into its counterpart on
3
the printer (7).
4
3. To secure the applicator lock it in place by
5
loosening the hinge screw (4), slide the hinge
6
lock (3) under the hinge and tighten the screw
again.
4. Pivot the applicator towards the printer making
7
sure that the cable of the plug (6) does not get
jammed between the components.
5. Use the turn-wheel screw (6) to fix the appli-
cator to the printer.
6. Raise the transportation lock to ensure the
unhindered movement of the lift cylinder.
1
2
1
2
3
15