7
Trouble shooting -- indication of malfunction
7.1
Trouble shooting
If you have problems operating your max-e, see whether you can remove
them with the help of the following instructions.
Problem
max-e cannot be turned on
Batteries don't charge
Power shafts do not emerge on one or
both sides.
Pressure is not reached
7.2

Indication of malfunction

The display indicates malfunction as follows.
7.2.1
Possible indication of malfunction
F
All indicated malfunctions can be confirmed by the + key.
Malfunction of the control unit
Low voltage
Parameter
Radio transmitter
Radio receiver
Software
Unidentified
Check and potential problem solving
Is the charger connected to the max-e?
If so, disconnect the charging cable and plug in the power cable
Is the battery pack or the control unit empty?
If so, charge the batteries and the control unit.
Are the fuses damaged?
If so, exchange the fuses.
If there is still a problem turning on the max-e, please contact
your dealer.
Please contact your dealer
Loosen set screw of the horizontal adjustment (located directly on the
housing) and screw it tight again (check the mounting width).
Loosen set screw of the horizontal adjustment (located directly on the
housing) and screw it tight again (check the mounting wi dth).
If there is still a problem, please contact your dealer
Explanation
Batteries of the control unit are under voltage
Parameter in EEPROM are false
Error in the transmitter of the radio module
Error in the receiver of the radio module
Error when running the control unit's software
Invalid error code (error of software)
27
max-e
Error!
Drive
Pressure not reached
Acknowledge with +