Evaluation of Situations during Speakerphone Automatic
Dialing without Confirmation
Situation
Silence or busy tone is heard
upon seizure
Busy tone
Talk or silence
Continuous tone (PBX)
Ringing tone is terminated
before 10 rings (or as
programmed) are reached
Ringing tone with 10 rings (the
count can be defined)
to
,
valid switch password(switch
activation)
Warning
Be sure to disable your voice mailbox, fax machine or any other
equipment connected to the called numbers to avoid premature
answering. This would terminate the dialing automatically.
Call Termination (Outgoing and Incoming Calls)
2N TELEKOMUNIKACE a.s., www.2n.cz
ST Activity
This has no influence on the operation; the
with any line status and only then evaluates the situation
The
ST
hangs up in approximately 2 seconds and dials the
following number
The
ST
waits for a defined timeout (logon time), then hangs
up and dials the following number
The
ST
hangs up in approximately 2 seconds and dials the
following number
This is considered as a successful call, the call continues for
the defined period of time (maximum call time). The message
is played back once.
The
ST
hangs up and dials the following number
These digits are interpreted as the switch control password
beginning
Dialing type 3 hangs up and calls next number,
Dialing type 4 hangs up and stops calling.
Dialing type 4 consider such call as a successfull, even if
ringing tone is not detected.
ST
executes dialing