2.4 Mounting - Compact version

Safety
Installing the telephone line cable, ensure that the user cannot touch the
conductors and is protected against an electrical accident by a minimum
isolation distance of 1.5 mm, or an isolation barrier of a minimum break--
down voltage of 1,500.
Prior to Mounting
Drill holes into the lift cabin wall as shown in the drawing or as printed 1:1 on the
product package. The larger hole is intended for cable passage. Round the hole edges
to avoid cable damage!
Note: The two 2.5 mm large holes in the window area are used where the mounting
panel rear is inaccessible. The 2.5 mm diameter is suitable for all wall mounting
options using plywood, chipboard, laminated plastic etc. with the aid of the screws
included. For front metal panel wall mounting drill M4 threaded holes.
2N TELEKOMUNIKACE a.s., www.2n.cz
25/82