Tip
To access connectors at the bottom edge of the board without cover
removal, just loosen cover screws gently and slide the cover upward.
Applies to HW version 7 and higher, when amplifier module is not
mounted.
Description of terminals
Telephone line
Polarity does not matter. Can be connected directly to a private telephone
network (PSTN), PBX or GSM gateway line.
CAUTION – more than one unit may not be connected to a single line!!!
voltage
12 – 24V DC voltage,any polarity
control
ALARM
*)
contact
switching or breaking contact
control
voltage
12 – 24V DC voltage,any polarity
control
CANCEL
*)
contact
switching or breaking contact
control
Indicator
Indicators (backlit pictograms), max. 24 V / 2× 200 mA, supplied from an
connecting
external power supply, the connection layout must be maintained.
terminals *)
External
External microphone is available on request. Switching between onboard
microphone
and external microphone is automatic (external microphone is detected).
connector
***)
External
For a request, loudspeaker can be equpped with cable. In this case, it is
loudspeaker
connected here.
connector
2N TELEKOMUNIKACE a.s., www.2n.cz
Emergency call activation
Emergency call deactivation