14.2 Piping diagram: Indoor unit

A
C
a2
f
c2
c1
C
a1
f
C
b1
f
C
b2
f
ERGA04~08DAV3(A) + EHVZ04+08S18+23DA6V+9W7
Daikin Altherma 3 R F
4P618957-1 – 2020.03
X
j
o
M
M3S
i
j
h
f
g
k
q
r
p
k
A Water side
B Refrigerant side
C Field installed
a1 Space heating water IN (additional/direct zone)
a2 Space heating water OUT (additional/direct zone)
b1 Space heating water IN (main/mixed zone)
b2 Space heating water OUT (main/mixed zone)
c1 Domestic hot water: cold water IN
c2 Domestic hot water: hot water OUT
d1 Gas refrigerant IN (heating mode; condenser)
d2 Liquid refrigerant OUT (heating mode; condenser)
e Plate heat exchanger
f Shut-off valve for service (if equipped)
g Expansion vessel
h Magnetic filter/dirt separator
i Safety valve
j Air purge
k Drain valve
l Pump (additional/direct zone)
m Check valve
n Flow sensor
o Backup heater
p Water filter (main/mixed zone)
q Capillary tube
r Pump (main/mixed zone)
B1PW Space heating water pressure sensor
B1PW
n
R1T
R2T
R8T
R5T
l
m
R4T
k
M1S
m
M
R7T
X
14
Technical data
|
B
B2PR
d1
e
d2
R3T
3D112187A