To Connect The Domestic Hot Water Pump; To Connect The Alarm Output; To Connect The Space Heating On/Off Output - Daikin Altherma 3 R F Installer's Reference Manual

Hide thumbs Also See for Altherma 3 R F:
Table of Contents

Advertisement

7.9.12 To connect the domestic hot water pump

7.9.13 To connect the alarm output

7.9.14 To connect the space heating ON/OFF output

ERGA04~08DAV3(A) + EHVZ04+08S18+23DA6V+9W7
Daikin Altherma 3 R F
4P618957-1 – 2020.03
2 Fix the cable with cable ties to the cable tie mountings.
1 Connect the domestic hot water pump cable to the appropriate terminals as
shown in the illustration below.
M
M2P
1~
1 2
X1M
2 Fix the cable with cable ties to the cable tie mountings.
1 Connect the alarm output cable to the appropriate terminals as shown in the
illustration below.
b
7 9
X1M
X1M
YC
Y1
a
A4P
a
Installation of EKRP1HBAA is required.
b
Prewiring between X2M/7+9 and Q1L (= thermal protector backup heater). Do NOT change.
2 Fix the cable with cable ties to the cable tie mountings.
1 Connect the space heating ON/OFF output cable to the appropriate terminals
as shown in the illustration below.
X2M
X5M
X2M
X5M
A5P
7
Installation
|
Installer reference guide
91

Advertisement

Table of Contents
loading

Table of Contents