10 Technical data
10.1

Piping diagram: Indoor unit

A
C
a2
f
c2
c1
C
a1
f
C
b1
f
C
b2
f
A
Water side
B
Refrigerant side
C
Field installed
a1
Space heating water IN (additional/direct zone)
a2
Space heating water OUT (additional/direct zone)
b1
Space heating water IN (main/mixed zone)
b2
Space heating water OUT (main/mixed zone)
c1
Domestic hot water: cold water IN
c2
Domestic hot water: hot water OUT
d1
Gas refrigerant IN (heating mode; condenser)
d2
Liquid refrigerant OUT (heating mode; condenser)
e
Plate heat exchanger
f
Shut-off valve for service (if equipped)
g
Expansion vessel
h
Magnetic filter/dirt separator
i
Safety valve
j
Air purge
k
Drain valve
l
Pump (additional zone/direct zone)
m
Check valve
n
Flow sensor
Installation manual
30
X
j
o
M
M3S
R8T
R5T
i
j
h
g
k
q
r
p
k
B1PW
n
R1T
R2T
l
m
R4T
k
M1S
m
M
R7T
X
o
Backup heater
p
Water filter (main/mixed zone)
q
Capillary tube
r
Pump (main/mixed zone)
s1
Liquid refrigerant IN (cooling mode; evaporator)
s2
Gas refrigerant OUT (cooling mode; evaporator)
B1PW
Space heating water pressure sensor
B2PR
Refrigerant pressure sensor
M1S
3-way valve (mixing valve for the main/mixed zone)
M3S
3-way valve (space heating/domestic hot water)
R1T
Thermistor (heat exchanger – water OUT)
R2T
Thermistor (backup heater – water OUT)
R3T
Thermistor (liquid refrigerant)
R4T
Thermistor (heat exchanger – water IN)
R5T, R8T
Thermistor (tank)
R7T
Thermistor (main/mixed zone – water OUT)
Screw connection
Flare connection
Quick coupling
Brazed connection
B
B2PR
s2
d1
e
d2
R3T
s1
3D112187C
EHFZ03S18DJ3V
Daikin Altherma 3 R F
4P596818-1D – 2021.10

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehfz03s18dj3v