14.8 ESP curve: Indoor unit

Installer reference guide
208
Note: A flow error will occur when the minimum water flow rate is not reached.
A (kPa)
70
60
50
40
30
20
10
0
0
5
10
A External static pressure in the space heating circuit
B Water flow rate through the unit in the space heating circuit
C Operation range
Additional/direct zone
Main/mixed zone
Dashed lines: Operation area is extended to lower flow rates only in case the unit
operates with heat pump only. (Not in startup, no backup heater operation, no
defrost operation.)
Notes:
Selecting a flow outside the operating area can damage the unit or cause the unit
to malfunction. See also the minimum and maximum allowed water flow range in
the technical specifications.
Water quality must be according to EU directive 98/83 EC.
C
15
20
25
30
4D112013
ERGA04~08DAV3(A) + EHVZ04+08S18+23DA6V+9W7
35
B (l/min)
Daikin Altherma 3 R F
4P618957-1 – 2020.03