Command
AT+MS=<Modula
tion>, [Auto-
mode], [Send
Minbaud, Send
Maxbaud],
[Receive Min-
baud, Receive
Maxbaud]
(continued)
AT\N<n>
ATO<n>
Description
B103
Bell 103
B212
Bell 212
Parameter Automode:
The optional parameter automode determines whether the INSYS Modem 336 LL
2D/4D 5.x Originate / Answer automatically adjusts to the desired modulation type.
The following values may be used:
0
Automatic modulation adjustment switched off
1
Automatic modulation adjustment switched on
Parameter Reception Minbaud:
The optional parameter minbaud determines the lowest possible baud rate for INSYS
Modem 336 LL 2D/4D 5.x Originate / Answer reception.
Parameter Reception Maxbaud:
The optional parameter maxbaud determines the highest possible baud rate for INSYS
Modem 336 LL 2D/4D 5.x Originate / Answer reception.
Parameter Send Minbaud:
The optional parameter minbaud determines the lowest possible baud rate which the
INSYS Modem 336 LL 2D/4D 5.x Originate / Answer uses for sending.
Parameter Send Maxbaud:
The optional parameter maxbaud determines the highest possible baud rate which the
INSYS Modem 336 LL 2D/4D 5.x Originate / Answer uses for sending.
Select error correction
This command determines which type of error correction should preferably be used for
subsequent connections.
Switching off error correction (normal buffered mode)
AT\N0
AT\N1
Bit direct mode (only for special data formats)
AT\N2
Selects V.42LAP-M or MNP 4 error correction. If no error corrected con-
nection can be established, the modem will hang up.
AT\N3
Selects V.42LAP-M or MNP 4 error correction. If such a connection can-
not be established, the modem will attempt to establish a connection
that is not error corrected. (default)
AT\N4
Selects exclusively a V.42 LAP-M connection.
Dials exclusively MNP 4 connections.
AT\N5
Return to online data mode
If the INSYS Modem 336 LL 2D/4D 5.x Originate / Answer is in online command mode, it
will return to online data mode. If the INSYS Modem 336 LL 2D/4D 5.x Originate / An-
swer is in offline command mode, it will report ERROR.
ATO0
Return to online data mode.
ATO1
Before the modem switches to online data mode, a retrain procedure is