Overview Of Mains Filters - Keba ServoOne CM-P BG1 Operation Manual

Passive supply unit
Table of Contents

Advertisement

A.7.1

Overview of mains filters

Mains input current I
≤ 25 A
IN
Max. motor cable length [m]
4
EMC25.120-UR EMC25.240-UR
C2
8
EMC25.120-UR EMC25.240-UR
16
EMC25.240-UR
Category
4
EMC25.120-UR
C3
8
EMC25.120-UR
16
EMC25.120-UR
KEBA article designation
EMC25.120-UR
EMC25.240-UR
EMC25.600-UR
Table A.9
Selection, mains filter for SOCM-P.0010 / SOCM-P.0110
Mains input current I
≤ 53 A
IN
Max. motor cable length [m]
4
EMC53.120-UR
C2
8
EMC53.240-UR
16
EMC53.240-UR
Category
4
EMC53.120-UR
8
EMC53.120-UR
C3
16
EMC53.120-UR
KEBA article designation
EMC53.120-UR
EMC53.240-UR
EMC53.600-UR
Table A.10
Selection, mains filter for SOCM-P.0022 / SOCM-P.0122
ID no.: 1400.201B.5-00
1
20
30
40
50
N/A
KEBA article no.
0996.2027
0996.2026
0996.2025
20
30
40
50
EMC53.240-UR
EMC53.600-UR
EMC53.600-UR
N/A
EMC53.600-UR
N/A
KEBA article no.
0996.2024
0996.2023
0996.2022
Date: 02/2020
60
70
80
90
100
EMC25.600-UR
N/A
EMC25.600-UR
N/A
N/A
60
70
80
90
100
N/A
EMC53.240-UR
120
140
240
300
EMC25.240-UR
EMC25.600-UR
EMC25.600-UR
EMC25.240-UR
120
140
240
300
EMC53.240-UR
EMC53.600-UR
EMC53.240-UR
EMC53.600-UR
N/A
Operation Manual Supply Unit SO CM-P BG1+2
600
600
51