Connection Example, Supply Unit 3 X 230 V - Keba ServoOne CM-P BG1 Operation Manual

Passive supply unit
Table of Contents

Advertisement

Electrical installation
1
Electrical installation
ID no.: 1400.201B.5-00

4.15.2 Connection example, supply unit 3 x 230 V

16
15
ϑ
4
5
6
L1
L1.1
L1
L1.1
L2
L2.1
L2
L2.1
L3
L3.1
L3
L3.1
3
1
2
25
L1 N
L1 L2 L3
L1´ L2´
PE
3 x 230 V
1 x 400 V
Figure 4.18
Connection example, (schematic depiction) 3 x 230 V
Date: 02/2020
11
24 V
X2
10
GND
9
X3
X3
n.c.
X1
20
ϑ
X5.1
BR
21
BR
X6
TP
X6
X6
X11
X5
X12
U
X8
X7
V
L1
L2
L3
L1
n.c.
L2
W
19
7
8
18
13
14
2
3
2
2
Motor
Motor
3~
ϑ
3~
Key to connection example
(1)
12
(2)
(3)
+24 V
GND
(4)
DC Link+
(5)
DC Link -
(6)
X4
(7)
X5.2
(8)
X9
X7
(9)
(10)
(11)
X8
X10
(12) (21) (22) (23)
(13)
X13
X14
22
(14)
23
U
U
(15)
V
V
W
W
(16)
(17)
(18)
(19)
(20)
17
PE
(25)
Table 4.12
2
2
3
3
NOTE:
2
The supply unit does not protect the upstream components
Motor
ϑ
3~
ϑ
(3, 5, 6) against thermal or electrical hazards. Corresponding
protective measures are to be taken.
Operation Manual Supply Unit SO CM-P BG1+2
Designation
Mains fuses for DC link supply
Mains fuse for switched-mode power supply
Mains contactor with protection circuit (optional)
Programmable switching contact for mains contactor
Mains choke (accessory)
Mains filter (accessory)
AC mains connection (power supply)
AC mains connection (24 V switched-mode power supply)
Busbars DC link
Busbars 24 V DC (PELV)
Supply unit (SO CMP)
See Operation Manual Axis Controller (SO CM)
Switch cabinet
Field
External braking resistor with temperature monitoring
Backing plate
Backing plate earthing
PE - protective earth conductor connection
Series protective earth conductor connection to the next
device
Cross-communication
Cable protection 6 A gG
Key to connection example
38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents