Diagnostics; Status Indication Led - Keba ServoOne CM-P BG1 Operation Manual

Passive supply unit
Table of Contents

Advertisement

5

Diagnostics

5.1

Status indication LED

ERR
Voltage
LED red (ERR)
LED green (Voltage)
Figure 5.1
Significance of the status LEDs
NOTE:
You will find details on the LED messages in the ServoOne CM device help
(ID. no.: 1400.209B.x)
DO00
DO03
DO01
DO04
DO02
GND
X6 / State
X5 / DO05
ID no.: 1400.201B.5-00
1
Diagnostics
Diagnostics
Supply unit error status (flashing code)
Status mains supply available
Date: 02/2020
Green LED Voltage
Behaviour
(Operating indication)
Off
-
Ready, the DC link is not connected to the
Flashing slowly
system.
Supply unit is in the pre-charging phase,
Flashing quickly
can take a few seconds.
Supply unit is pre-charged and connected
On
to the system.
Table 5.1
Significance of the status LEDs, ServoOne CM-P Supply Unit
Operation Manual Supply Unit SO CM-P BG1+2
Red LED ERR
(Error indication)
No error and no warning
There is a warning, however the supply unit
is ready.
-
There is an error, the DC link is
disconnected from the system. Error
message appears in the axis modules.
39