Technical Data, Brake Chopper Bg2; Ambient Conditions - Keba ServoOne CM-P BG1 Operation Manual

Passive supply unit
Table of Contents

Advertisement

NOTE:
In the overall axis group, a DC link capacitance of ≥ 100 µF/kW (for 3 x 400 V)
or ≥ 170 µF/kW (for 3 x 230 V), referred to the highest rated power that
occurs, must be provided. This capacitance is determined by adding together
the capacitances of the individual devices. The root mean square of the active
power for a load cycle is defined as the active power.
A.2.1

Technical data, brake chopper BG2

Device
Mains voltage
Brake chopper power electronics
Brake chopper switching threshold
Overvoltage protection
Continuous braking power [kW]
Peak braking power for maximum 0.5 s *)
Maximum ohmic resistance of an externally
connected braking resistor
Minimum ohmic resistance of an externally installed
braking resistor
Supply unit "with integrated braking resistor" (version SO CM-P.xxxx.11xx.x)
Continuous braking power [kW]
Peak braking power for maximum 0.5 s *)
Ohmic resistance of the integrated braking resistor
2
*) After this time shutdown is initiated based on I
x t
Table A.4
Brake chopper BG2
ID no.: 1400.201B.5-00
1
Unit
SOCM-P.0022 / SOCM-P.0122
V AC
230
400
480
V
411
652
765
V
446
687
800
kW
3.5
6
6
kW
20
28
30
50
90
90
8
15
20
W
200
kW
6
28
Date: 02/2020
DAMAGE TO THE DEVICE DUE TO CONNECTION OF AN EXT.
CAUTION!
BRAKING RESISTOR!
x Carelessness may result in significant damage.
Please note that no additional external braking resistor is allowed to be connected to the device
model "with integrated braking resistor".
A.3

Ambient conditions

Ambient conditions
Device: IP20 - exception terminals: IP10 (protection against touching, back of
Protection
hand)
Accident prevention regulations
As per the local regulations (in Germany e.g. BGV V3)
Up to 1000 m above MSL, higher with power reduction
Installation altitude
(1% per 100 m, max. 2000 m above sea level)
Pollution degree
2
Built-in unit, only for vertical mounting in a switch cabinet with min. IP4x
Type of mounting
protection, on using STO safety function min. IP54
Table E.5
Ambient conditions, ServoOne CM
Climatic conditions
As per EN 61800-2, IEC 60721-3-2 class 2K3
In transit
Temperature
Relative atmospheric humidity
1) The absolute humidity is limited to max. 60 g/m³. This means, at 70 °C for example, that the relative atmospheric humidity
may only be max. 40 %.
2) The absolute humidity is limited to max. 29 g/m³. So the maximum values for temperature and relative atmospheric humidity
stipulated in the table must not occur simultaneously.
3) The absolute humidity is limited to max. 25 g/m³. That means that the maximum values for temperature and relative atmos-
pheric humidity stipulated in the table must not occur simultaneously.
Table A.6
Climatic conditions, supply unit ServoOne CM-P
Operation Manual Supply Unit SO CM-P BG1+2
ServoOne CM-P supply unit
ServoOne CM-P supply unit
1)
-25 °C to +70 °C
95 % at max. +55 °C
47