Technical Data, Supply Unit Bg2 - Keba ServoOne CM-P BG1 Operation Manual

Passive supply unit
Table of Contents

Advertisement

1
ID no.: 1400.201B.5-00
DAMAGE TO THE DEVICE DUE TO CONNECTION OF AN EXT.
CAUTION!
BRAKING RESISTOR!
x Carelessness may result in significant damage.
Please note that no additional external braking resistor is allowed to be connected to the device
model "with integrated braking resistor".
Date: 02/2020
Operation Manual Supply Unit SO CM-P BG1+2
A.2

Technical data, supply unit BG2

Device
Input, mains side
Mains voltage U
± 10 %, 3 times
N
Continuous current [A
], typical
AC eff
Peak current [A
], typical
AC
Continuous power, typical (depending on mains
impedance)
Rectifier power dissipation
Asymmetry of the mains voltage
Frequency
Max. cable cross-section of the terminals X12
DC link output
DC link voltage typical *
Continuous current
Peak current 2 x I
for 1 s
N
mains choke not required
Continuous power P
N
Peak power 2 x P
for 1 s
N
DC link capacitance only CM-P
Required total DC link capacitance for continuous
power
Permissible DC link capacitance SOCM + CM-P
Power dissipation P
in the interior
rated
* Load-dependent
Table A.3
Technical data, ServoOne CM-P BG2
CAUTION!
DAMAGE TO THE SUPPLY UNIT DUE TO OVERLOAD IN THE DC LINK!
x Carelessness may result in significant damage.
The maximum overall capacitance of the multi-axis system DC link must not exceed the value
stated.
46
Unit
SOCM-P.0022 / SOCM-P.0122
V AC
230
400
480
A
46
46
38
A
92
92
76
kVA
18.5
32
W
110
±3 % max.
50-60 Hz ± 10%
1.5 ... 16 mm
2
(fine-stranded cable with/without
ferrules)
V DC
325
565
678
A DC
39
39
32
A DC
78
78
64
kW
12.5
22
kW
25
44
µF
840
µF
2200
µF
4000 (3160 + 840) max.
W
130

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents