Mechanical installation
Mechanical installation
ID no.: 1400.201B.5-00
3.4.1

Dimensions (housing with heat sink)

ServoOne CM-P
Supply unit BG1
Type
SOCM-P.0010
Weight
2.65 kg
B (width)
55
H (height)
H1
H2
T (total depth)
T1
A
27.5
A1
-
C
Side clearance
Screws
2 x M4
All dimensions in mm
Table 3.1
Dimensions for wall mounting
NOTE:
The supply unit must always be fitted to the left of the axis controllers.
The highest power axis controller should be close to the supply unit. For dou-
ble-axis and triple-axis controllers it is the total power that counts.
Date: 02/2020
Supply unit BG2
SOCM-P.0022
5.1 kg
110
310
299
6
241
222
27.5
55
5
Direct butt mounting
4 x M4
Operation Manual Supply Unit SO CM-P BG1+2
3.4.2

Dimensional sketches, wall mounting

B
A
C
Figure 3.4
Dimensional drawing, supply unit BG1, for dimensions see Table 3.1