2.5

Misuse

Our devices are:
Not intended for installation in vehicles. Deployment of the device in mobile
y
equipment is classed as non-standard ambient conditions and is permissible
only by special agreement.
Not intended for installation in environments with harmful oils, acids, gases,
y
vapours, dusts, radiation etc.
Not approved for usage in special applications (e.g. in potentially explosive
y
atmospheres or areas in which there is a risk of fire).
Not approved for usage outside a switch cabinet.
y
y
Not approved for the generation of high-frequency onboard
networks for which the devices are not designed.
Note:
The use of devices in warehouse storage and retrieval systems that are
operated inside and outside the rack aisle on rails is allowed provided
the vibration does not exceed the maximum standard values 3M1 as per
DIN EN 60721-3-3.
2.6

Responsibility

Electronic devices are not fail-safe. The installer and/or operator of a complete machine
or system is responsible:
y
For ensuring the drive is rendered safe if the device fails
For ensuring the safety of personnel and machinery
y
For ensuring the complete machine is in correct working order
y
For the risk assessment on the complete machine or system according to
y
DIN EN 12100:2011 (formerly DIN EN 14121:2007) and EN ISO 13849-1 (for-
merly DIN EN 954-1)
In EN 60204-1:2006 "Safety of machinery", pay attention to:
The topic of "Electrical equipment of machines". The safety requirements on
y
electrical machines defined there are intended to protect personnel and machin-
ery or systems.
ID no.: 1400.201B.5-00
Safety
Safety
Date: 02/2020
The emergency stop function (as per EN 60204) shuts down the supply of pow-
y
er to a machine, which results in the drives coasting down in an uncontrolled
manner. To avert hazards, check whether it is appropriate:
− To keep individual drives in operation
− To initiate specific safety procedures
− To incorporate a Safe Torque Off function (Safe Torque Off: movement stop
by "switching off the electrical supply" or STO)
2.7
Relevant laws, standards and directives
applied
For information on the laws, standards and directives applied by KEBA, refer to the
declaration of conformity.
Note:
Depending on the specific application for the devices, other laws, standards
and directives with provisions on "safety" may apply. If necessary, contact the
machine or system manufacturer.