Mechanical installation
Mechanical installation
ID no.: 1400.201B.5-00
3.2

Mounting clearances

CAUTION!
Damage to the device due to incorrect installation conditions!
The device may suffer irreparable damage if the conditions are not met.
x The minimum clearances stated in the figure below apply to all devices (MotionOne CM,
ServoOne CM-P and ServoOne CM).
x The clearance above the devices is important to prevent the build-up of heat. The clearance
underneath and at the front is necessary to permit correct cable laying.
≥ 130
SOCMP-BG1
≥ 150
*)
Figure 3.2
Mounting clearances, SystemOne CM-P supply unit
Date: 02/2020
≥ 300
Operation Manual Supply Unit SO CM-P BG1+2
≥ 130
SOCMP-BG2
≥ 200
*)
*) The bending radius of the connection cables must be taken into account:
The mains connection cable for the supply unit is definitive for the clearance underneath.
Bending radius mains cable up to 3 x 10 mm
2
(for SOCM-P-BG1)
2
Bending radius mains cable up to 3 x 16 mm
(for SOCM-P-BG2)
Figure 3.2
Mounting clearances, SystemOne CM-P supply unit
14
≥ 300
Approx. 48 to 98 mm (depending on cable type)
Approx. 150 to 200 mm (depending on cable type)