USE OF THE DEVICE WITH THE POWER SOURCE
Socket for the power source is arranged on the left side of the device. To use the device
with the power source, connect the power source connector to the device, install the
power source plug into the socket outlet, and press the «START/STOP» button.
When fi nished, turn off the device by pressing the «START/STOP» button, unplug the
power source from the socket outlet and disconnect the power source connector
from the device.
NOTE! If there is no battery in the device, turning off the power source will result in
zeroing of measurement results stored in the device memory and set date and time. If
you do not want to make the data erased, do not remove the batteries from the device
when using the power source.

SETTING DATE AND TIME

Date and time can be set after installing batteries. Setting the date and time guarantees
the preservation of measurement results with indicated correct date and time. The de-
vice can be used without setting the date and time.
Press and hold the SET button until the display fl ashes the value of the year.
Date and time are set in the following order: year, month, day, hour and minute.
1. Setting the Year
Use the
button to increase and
button to confi rm and to pass to the next step.
2. Setting the Month
button to increase and
Use the
SET button to confi rm and to pass to the next step.
3. Setting the Day
Use the
button to increase and
button to confi rm and to pass to the next step.
4. Setting the Time
Watch uses a 12-hour time format of day. Use the
to decrease the hour or minute value. Press the SET button to confi rm the settings. To
stop the setting, press the «START/STOP» button.
IMPORTANT! If the date and time are set, then when turned off the device display will
show the current time.
button to decrease the year value. Press the SET
button to decrease the month value. Press the
button to decrease the day value. Press the SET
button to increase and

CORRECT POSITION DURING MEASUREMENT

Sit at the table, let the chair and
table support your back and
arm, and keep your feet fl at on
the fl oor as you take the blood
pressure measurement (Fig. 4).
Make sure that the measure-
ment location on the upper
arm is at approximately the
same height as the heart, and
that the forearm is extended naturally on the table and does not move.
You may lie on your back and take the measurement (Fig.6). Look at the ceiling, stay calm,
and do not move your neck or body during the measurement. Again, make sure that the
measurement location on the arm is at approximately the same height as the heart.
Measured values may vary slightly, depending on the position during the
measurement. If the cuff is above/below the level of the heart, resulting reading
may be incorrect (lower/higher)

CUFF PREPARATION

Fig.7
button
Fig.8
5
Fig.4
Fig.5
1. Apply the cuff to your left upper arm so that the air
tube is directed to your palm (Fig. 7). If the measurement
on your left arm is diffi cult, you may use your right arm. In
this case remember that the readings may diff er by 5-10
mmHg and even more.
2. Wrap the cuff around your upper arm so that the bottom
of the cuff is approximately 2-3 cm above your elbow. Air
tube should be directed towards the palm (Fig. 8).
Fig.6