Fan Cage Replacement; Remove A Fan Cage (Upper Tray) - Lenovo ThinkAgile VX7820 User Manual

Table of Contents

Advertisement

Watch the procedure. A video of the replacement process is available:
YouTube
Youku
Figure 63. Fan installation
Step 1.
Align the fan with its opening in the front of the chassis and insert, making sure that the rails on the
fan fit into the slots in the fan opening.
Step 2.
Push the fan into chassis until it stops and the latch engages.
If you are done performing installation or maintenance procedures at the front of the chassis, install the front
cover. See "Install the front cover" on page 132.

Fan cage replacement

Fan cages are in the upper and lower compute trays or optional storage tray that are accessed from the front
of the server. Procedures for removing and installing fan cages in the upper and lower trays are different.

Remove a fan cage (upper tray)

The upper fan cage is in the upper compute tray or optional storage tray that is accessed from the front of
the server. After removing the upper tray, turn it upside down, press the fan cage releases, and pull the fan
cage toward the front of the tray to remove it; then, disconnect the fan cage electrical connector.
S002
CAUTION:
The power-control button on the device and the power switch on the power supply do not turn off the
electrical current supplied to the device. The device also might have more than one power cord. To
.
Chapter 9
Hardware replacement procedures
121