Assembly and Installation
Page 26
5.4

Installing and Connecting the Lamp

DANGER
Switch off at the mains before installing and connecting the lamp.
The lamp must be installed before it can be commissioned. UVC radiation is damaging
to the eyes and skin.
The UV system must be installed as instructed before the lamp can be commissioned.
Do not make any unauthorized changes to the lamp connection cable already installed.
IMPORTANT
Protective gloves (cotton gloves) should be worn when installing the lamp.
Do not touch the lamp with your bare hands.
Fingerprints become etched in the glass and may lead to premature failure. Remove
any fingerprints prior to installation using a cloth that has been soaked in alcohol.
Insert the O-rings provided in the correct grooves on the tube clamps.
Remove the lamp from its packaging.
Extend the lamp cables on both sides of the lamp slightly so that the connections lie at the
ends of the radiation chamber ready for installation later.
Clean the lamp using the cloth provided.
Insert the lamp into the protective tube from the lid end. Allow approximately 5 cm of the
lamp cable to protrude.
At the lid end, push the spacer (glass tube) over the lamp cable until it locks into place on
the lamp. The lamp cable must protrude by approximately 3 cm. If necessary, use tweezers
or small pliers to pull the lamp cable out slightly.
Connect the lamp cable to the connection terminal of the lamp connection cable.
Push the lamp connection cable carefully into the spacer holding onto the spacer for as
long as possible.
Push the lamp cover onto the tube clamp and secure it.
On the motor side, push the spacer (glass tube) over the lamp cable until it locks into place
on the lamp. The lamp cable must protrude by approximately 3 cm. If necessary, use
tweezers or small pliers to pull the lamp cable out slightly.
Connect the lamp cable to the connection terminal of the lamp connection cable.
Push the lamp connection cable carefully into the spacer.
Push the lamp cover onto the tube clamp and secure it.
5.4.1

Mounting the Safety Shield on the Wiper Motor

After the lamp has been installed, the safety shield should be mounted on the wiper motor.
Pull the safety shield (split tube made of transparent plastic) apart at the split carefully and
push it down over the motor supports.
The safety shield must be flush against the radiation chamber. The hole in the safety shield
is for the protection tube clamp.
®