3.7.3

Display Message Command Format (Matrix Display)

3m8 and 3m12 remotes.
|<AA><DM>|<Timeout>|<Flash>|<Slide On>|<Scroll>|<Scroll Count>|<Data>!
where:
| = Pipe character (0x7C)
AA = Two byte address, ASCII digits
DM = Two byte command, ASCII characters
| = Pipe character (0x7C)
<Display Timeout> = Milliseconds to display the message (N/A for scroll). 32,767 (32 seconds) is the maximum timeout.
Values above the number indicates an indefinite display.
| = Pipe character (0x7C)
<Flash> = "Y" or "N"
| = Pipe character (0x7C)
<Slide On> = "Y" or "N"
| = Pipe character (0x7C)
<Scroll> = "Y" or "N"
| = Pipe character (0x7C)
<Scroll Count> = Number of times to scroll the message or "A" for annunciator msg cmd (learn enable = OFF)
| = Pipe character (0x7C)
<Data> = Text to display
! = Exclamation point character (0 x 21)
Command
DM
GT
ST
DI
DO
GR
SR
GB
GV
DC
TP
Time and date is sent from the remote display depending on the current remote display time and date format;
Time and date are sent to the remote display in ISO format:
USA Format: HH:MM:SS AM/PM MMM/DD/YYYY
ISO Format: HH:MM:SS YYYY-MM-DD
If the real time clock is disabled in the remote display, an error message is sent back
Examples: Scroll the message "Rice Lake Weighing Systems" twice:
|00DM|0|N|N|Y|2|Rice Lake Weighing Systems!
Slide on and flash the message "DRIVE AHEAD" for 5 seconds:
|00DM|5000|Y|Y|N|0|DRIVE AHEAD!
<Data> is the six character message to display; If less than six characters, send spaces to
make it six characters; Some data may not be overwritten
Example: |00DMSTOP !
Get time and date; Information gathered is sent back to the indicator, allowing both the remote
display and indicator to match; This is not displayed on the remote display
Example: |00GT!
Set time and date
Example: |ST08:00:00 2003-01-31!
NOTE: Two spaces are required between time and date entries.
Get digital input state
Get digital output state
Get relay state; Relay 0-3, 0=Off=LL, state 1=LH, state 2=HL, state 3=On=HH
Set relay state (output relays only); Relay 0-1, state 1=On and 0=Off
Get the number of 5 x 7 Max6953 boards (0 = 7-seg, 2, 3 = 5 x 7)
Get the version number
Dump configuration parameters (for testing purposes only)
Temperature adjustment; Allows ±5% degree adjustment
Table 3-11. Display Message Command Format
Description
© Rice Lake Weighing Systems ● All Rights Reserved
Configuration
23