Nice ALTO100C Instructions And Warnings For Installation And Use page 6

Gate automation
Table of Contents

Advertisement

d
a
Connection
5
cascade
6
B
C
D
T
Connection
A - Power line
B - FLASH Flashing light output
C - Radio aerial
D - BUS input/output
E - STOP Input
F - SbS Input
G - Motor output without control unit
Note 1
Note 2
Note 3
Note 4
WARNING! – The cables used must be suited to the installation environment: for example, for indoor environments cable types
H03VV-F are recommended, and for outdoor environments, cable types H07RN-F.
5 – English
c
f
Connection
Star
G
Type of cable (minimum section values)
cable 3 x 1,5 mm²
cable 2 x 0.5 mm²
RG58 shielded cable type
cable 2 x 0.5 mm²
cable 2 x 0.5 mm²
cable 2 x 0.5 mm²
cable 3 x 1 mm²
c
e
Connection
"combined"
D
(ref.
and paragraph 3.3.4)
Max. admissible length
30 m
20 m
20 m (less than 5 m recommended)
20 m
20 m
20 m
10 m
E
b
f
E F
A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alto100m

Table of Contents