Nice ALTO100C Instructions And Warnings For Installation And Use page 31

Gate automation
Table of Contents

Advertisement

Table 11 - Led signals on control unit
LED BUS
Off
On
a pause
LED STOP
Off
On
LED SbS
Off
On
LED P1
Off
On
1 to 4
LED P2
Off
On
LED P3
Off
On
Status
Fault
Serious fault
Everything OK
Input status variation
BUS short circuit
Status
STOP input activated
Everything OK
Status
Everything OK
SbS input activated
Status
Everything OK
Memorisation in "Mode I"
Memorisation in "Mode II"
Wrong command
Memorisation OK
Deletion OK
Status
Everything OK
Everything OK
No devices have been learnt or
an error has occurred in learnt
devices
Device learning procedure
underway
Status
Everything OK
Everything OK
There is no memorised opening
angle
Indicates that the opening angle
learning phase is in progress
Action
Check that the unit is powered; check that the fuses have not been
activated; if this is the case check the cause of the fault and replace
them with other fuses with the same characteristics.
There is a serious fault; switch off the control unit for a few seconds;
if the status persists there is a fault and the electronic board must be
replaced.
Control unit works correctly.
A variation to the status of the inputs: SbS, STOP, activation of the
photocells, or when the radio transmitter is used, is normal.
An overload has been detected therefore the power to the BUS
switched off. Check by disconnecting the devices one at a time. To
restore power to the BUS simply send a command, for example with a
radio transmitter.
Action
Check the devices connected to the STOP input.
STOP input active.
Action
SbS input not active.
This is normal only if the device connected to the SbS input is
active.
Action
No memorisation underway.
This is normal during memorisation mode 1 which lasts maximum
10 s.
This is normal during memorisation mode 2 which lasts maximum
10 s.
Command received from a transmitter which is not memorised.
All devices successfully memorised.
All radio transmitters successfully deleted.
Action
"Slow" speed selected.
"Fast" speed selected.
Some faulty devices may be present; check and if necessary repeat
the device learning phase (see paragraph A.10).
It shows that the search for connected devices is underway (it lasts
maximum a few seconds).
Action
Operation with "half cycle" (semi-automatic).
Operation with "complete cycle" (automatic).
Perform the leaf opening and closing learning phase (read paragraph
7.2).
Indicates that the opening angle learning phase is in progress.
English – 30

Advertisement

Table of Contents
loading

This manual is also suitable for:

Alto100m

Table of Contents