Sure Cross
Performance P2-KR Gateway
®
Datasheet
®
The Sure Cross
wireless system is a radio frequency network with integrated I/O that operates in most environments to eliminate
the need for wiring runs.
For additional information, updated documentation, and a list of accessories, refer to Banner Engineering's website,
www.bannerengineering.com/wireless
WARNING:
Do not use this device for personnel protection
Using this device for personnel protection could result in serious injury or death.
This device does not include the self-checking redundant circuitry necessary to allow its use in
personnel safety applications. A device failure or malfunction can cause either an energized (on) or de-
energized (off) output condition.
Important:
Electrostatic discharge (ESD) sensitive device
ESD can damage the device. Damage from inappropriate handling is not covered by warranty.
Use proper handling procedures to prevent ESD damage. Proper handling procedures include leaving
devices in their anti-static packaging until ready for use; wearing anti-static wrist straps; and
assembling units on a grounded, static-dissipative surface.
Models
Models
Frequency
DX80G2M6S-P2-KR
2.4 GHz ISM Band
Configuration Instructions
Setting Up Your Wireless Network
To set up and install your wireless network, follow these steps.
Disconnect the power from your Sure Cross devices.
1. Configure the DIP switches of all devices.
2. If your device has I/O, connect the sensors to the Sure Cross devices. If your device does not have I/O, skip this step.
3. Refer to the wiring diagrams to apply power to all devices.
For housed models, the Gateway's LED 1 is solid green and the Node's LED 2 flashes red to indicate there is no radio
link to the Gateway.
For board-level models, the Gateway's LED is solid green and the Node's LED flashes red to indicate there is no radio
link to the Gateway.
4. Form the wireless network by binding the Nodes to the Gateway. If the binding instructions are not included in the
datasheet, refer to the product manual for binding instructions.
Original Document
182821 Rev. B
Wireless industrial I/O device with four selectable discrete inputs, four sourcing discrete
sourcing outputs, two universal analog inputs, and two 0 to 20 mA analog outputs
10 to 30 V dc power input
DIP switches for user configuration
Modbus serial interface
Site Survey analyzes the network's signal strength and reliability and displays the results on
the Gateway's LCD
Frequency Hopping Spread Spectrum (FHSS) technology ensures reliable data delivery within
the unlicensed Industrial, Scientific, and Medical (ISM) band
Transceivers provide bidirectional communication between the Gateway and Node, including
fully acknowledged data transmission
Lost RF links are detected and relevant outputs set to user-defined conditions
.
Environmental Rating
IP67, NEMA 6
18 January 2019
I/O
Inputs: Four selectable discrete, two 0 to 20 mA or 0 to 10 V analog
Outputs: Four sourcing discrete, two 0 to 20 mA analog
182821

Advertisement

Table of Contents
loading

Summary of Contents for Banner Sure Cross P2-KR

  • Page 1 Transceivers provide bidirectional communication between the Gateway and Node, including fully acknowledged data transmission • Lost RF links are detected and relevant outputs set to user-defined conditions For additional information, updated documentation, and a list of accessories, refer to Banner Engineering's website, www.bannerengineering.com/wireless WARNING: •...
  • Page 2: Configure The Dip Switches

    ® Sure Cross Performance P2-KR Gateway 5. Observe the LED behavior to verify the devices are communicating with each other. • For housed models, the Gateway's LED 1 is solid green and the Node's LED 1 flashes green to indicate it is communicating with the Gateway.
  • Page 3 ® Sure Cross Performance P2-KR Gateway Analog Input and Output Scale Use the DIP switch to select which current scale to use for all the device's analog inputs and outputs: 0 to 20 mA or 4 to 20 mA. When using a 4-20 mA sensor with a 0-20 mA input, the sensor uses the 4-20 mA section of the total range. Using a 4-20 mA with a 0-20 mA input allows you to determine when you have an error condition with the sensor.
  • Page 4: Terminal Blocks

    ® Sure Cross Performance P2-KR Gateway Note that a 220 ohm 0.1% resistor must be installed for a 0 to 20mA input. The resistor must be removed for an input defined as a 0 to 10V input. ® Wire Your Sure Cross Device Use the following wiring diagrams to first wire the sensors and then apply power to the Sure Cross devices.
  • Page 5: Led Behavior For The Gateways

    ® Sure Cross Performance P2-KR Gateway Wiring Diagrams for Discrete Outputs x ...C models, PWR in the wiring diagram Connecting power to the communication pins will cause permanent damage. For the DX8 refers to V+ on the wiring board and GND in the wiring diagram refers to V- on the wiring board. To power the sensor using the switch power output (SPx), replace the PWR with SPx in these wiring diagrams.
  • Page 6: Holding Registers

    For DXM Controllers with an internal DX80 radio, connect a computer to the DXM Controller using a USB or Ethernet connection. Download the most recent revisions of the configuration software from Banner Engineering's website: www.bannerengineering.com/wireless The USB to RS-485 adapter cable is not required for the DXM Controller. For standalone DX80 Gateway devices use: •...
  • Page 7: Environmental Specifications

    The Sure Cross wireless products were certified for use in these countries using the antenna that ships with the product. When using other antennas, verify you are not exceeding the transmit power levels allowed by local governing agencies. Consult with Banner Engineering Corp. if the destination country is not on this list.
  • Page 8 Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product.

This manual is also suitable for:

Dx80g2m6s-p2-kr

Table of Contents