INSTALLATION & OPERATION MANUAL, GAS TILTING SKILLETS,
MODELS: 30P-STGL, 30P-STGL-LX, 40P-STGL, 40P-STGL-LX,

SECTION 2, INSTALLATION INSTRUCTIONS

• Keep this appliance area free and clear of combustibles.
• Do not obstruct the flow of combustion and ventilation air.
• Allow adequate ventilation to unit. Install under exhaust hood.
• Keep this manual for future reference.
• This installation must conform with local codes or, in the absence of local codes, with
National Fuel Gas Code, ANSI Z223.1 – latest edition; or the Natural Gas Installation Code,
CAN/CGA–B149.1; or the Propane Installation Code, CAN/CGA-B149.2, as applicable.
• The griddle and its individual shutoff valve must be disconnected from the gas supply piping
system during any pressure testing of that system at test pressure in excess of ½ psig
(3.45 k/Pa).
• The griddle must be isolated from the gas supply system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures
equal to or less than ½" psig (3.45 k/PA).
• This unit is serviceable from the front. Do not install in such a manner that a service person
cannot remove front panels if provided.
• When installed, this appliance must be electrically grounded in accordance with local codes,
or, in the absence of local codes, with the National Electric Code, ANSI/NFPA No. 70 – latest
edition.
• In Canada, this installation must conform to C.S.A. Standard C22.2 Canadian Electrical Code.
• The wiring diagram adhesive label is located on the inside of the control box cover.
• The product must be installed in a room with adequate air supply for complete gas
combustion.
• Do not place on or directly against the unit any objects that would block air openings into the
combustion chamber.
• Suitable for use on combustible floors.
• Clearances from both combustible and noncombustible construction are 0" (0 mm) from side
walls, 10" (254 mm) from rear wall.
• This unit has a flexible cord wired into electrical system.
Part No. 10158R3
30P-STGM, 30P-STGM-LX, 40P-STGM, 40P-STGM-LX
CAUTION: BE SURE TO READ
6
2019-05-24