INSTALLATION & OPERATION MANUAL, GAS TILTING SKILLETS,
MODELS: 30P-STGL, 30P-STGL-LX, 40P-STGL, 40P-STGL-LX,
30P-STGM, 30P-STGM-LX, 40P-STGM, 40P-STGM-LX
UniVerse TILTING SKILLET WITH ELECTRONIC IGNITION
GENERAL INSTALLATION
1. Remove carton from skid, being careful not to dent or scratch finished surfaces of unit.
2. Inspect unit carefully for shipping damage. File claim with carrier immediately if damage is
found.
3. Remove screws holding unit to skid.
4. Transfer unit to desired position and make level and steady by adjusting feet to compensate
for floor irregularities. Bolt the flange feet to floor.
5. Raise skillet cover to full open position. Raise skillet by turning hand crank clockwise.
Check to make sure burners and carryover tube are in position and securely seated.
6. Lower skillet by turning hand crank counterclockwise until fully seated on frame. Skillet is
equipped with interlock switch, which does not permit burners to ignite until skillet is lowered
to less than 10 off normal horizontal cooking position.
NOTE: "LX" models may be raised or lowered using tilt switch after connecting to electrical
supply.
7. Gas service connections:
a. This unit is factory-adjusted for gas consumption of 93,000 BTU/Hour (on 30-gallon unit)
or 126,000 BTU/Hour (on 40-gallon unit) at the pressure indicated. Please read the
rating plate on top of control box. If this plate is marked for a different gas than that
supplied, notify your dealer immediately.
DO NOT CONNECT GAS LINES. Only a qualified installer or service man should make
the installation.
b. Use new 3/4 I.P.S. iron or steel pipe complying with ANSI Standard for Wrought-Steel
and Wrought-Iron Pipe B36 – latest edition, properly threaded, reamed, and free from
chips, oil, and dirt. If pipe dope is used, apply a moderate amount, leaving two end
threads bare. Gas connection is on the rear of the right console. Pipe in a gas shut-off
valve (not included), accessible to the operator.
c. Natural gas units are equipped with a pressure regulator factory-adjusted to give 3.5"
(89 mm) water column manifold pressure. The supply pressure must be at least 7" (178
mm) water column pressure.
Part No. 10158R3