INSTALLATION & OPERATION MANUAL, GAS TILTING SKILLETS,
MODELS: 30P-STGL, 30P-STGL-LX, 40P-STGL, 40P-STGL-LX,
30P-STGM, 30P-STGM-LX, 40P-STGM, 40P-STGM-LX
SECTION 5, TROUBLESHOOTING AND MAINTENANCE (Continued)
PROBLEM
1.
Uneven or poor heating.
2. Signal light out.
3. Unit fails to heat.
4.
No 110 Volts
output.
5. No gas to unit.
Part No. 10158R3
PROBABLE CAUSE
a.
Temperature control out
of calibration or
defective.
b.
Unit attached to wrong
gas supply.
c.
Combination gas control
set to wrong pressure.
a.
Burnt out bulb.
b.
Broken temperature
control.
c.
Loose electrical
connection.
a.
Circuit breaker is off.
b.
Malfunction of interlock
switch.
c.
Broken ignition module.
d.
Broken ignitor/sensor.
a.
Defective temperature
control.
b.
Broken temperature
sensor.
a.
Defective gas valve.
21
REMEDY
a.
Replace temperature
control.
b.
Compare to
specifications on data
plate.
c.
Adjust manifold
pressure to equal that
listed on data plate.
a.
Replace.
b.
Replace.
c.
Repair.
a.
Reset circuit breaker.
b.
Adjust or replace.
c.
Replace.
d.
Replace.
a.
Replace.
b.
Replace.
a. Replace.
2019-05-24