GENERAL INSTALLATION:
UNPACKING:
Immediately after unpacking, check for possible shipping dam-
age. If the tilting universe plus electric skillet is found to be dam-
aged, save the packing material and contact the carrier within 15
days of delivery.
Before installing, verify that the electrical service agrees with the
specifications on the rating plate located on the right side panel
as you face the front of the skillet. If the supply and equipment
requirements do not agree, contact your dealer.
LOCATION:
The installation location must allow adequate clearances for ser-
vicing and proper operation. A minimum front clearance of 36",
and rear clearance of 6" is required.
INSTALLATION CODES AND STANDARDS:
Your Tilting Universe Plus Electric Skillet must be installed in ac-
cordance with:
1. Provincial and local codes, with: USA state and local codes,
or in the absence of local codes, with: The National Electri-
cal Code ANSI/NFPA-70 (Latest Edition), or in the absence-
of local codes, with: Canada CSA C22.1 Canadian Electrical
Code, Part 1.
2. ANSI/NFPA Standard #96, "Vapor Removal from Cooking
Equipment", (Latest Edition), available from Tha National Fire
Protection Association, Batterymarch Park, Quincy, Massa-
chusetts (MA) 02269.
LEVELING AND ANCHORING THE SKILLET:
1. Place the skillet in the desired location of installation.
2. Place a carpenter's level on the top of the skillet pan and
turn the adjustable feet to level the skillet from side-to-side-
and front-to-back.
3. Mark hole locations on the floor through the anchoring
holes provided in the rear adjustable flange feet.
4. Remove the skillet from the anchoring holes marks that you
marked on the floor and drill a hole for each marking. After
all holes have been drilled, place the skillet back into original
position.
5. Check to make sure the skillet is still level. (See Step 2).
AMP PER LINE WIRE TABLE:
MODELS: 30P-STEL * 30P-STEM
EXPORT MODELS: 30P-STEL-LX * 30P-STEM-LX
3 pH, 4 Wire, 50Hz
Amps Per Line Wire
12 kW
220/380 Volt
12 kW
240/415 Volt
( EXPORT ONLY )
12 kW, 1 pH Unit, 60Hz
Amps Per Line
208 Volt
240 Volt
12 kW, 3 pH Unit, 60Hz
Amps Per Line
208 Volt
240 Volt
480 Volt

INSTALLATION

18.2
16.7
L # 1
L # 2
57.7
57.7
50.0
50.0
L # 1
L # 2
L # 3
33.0
33.0
33.0
29.0
29.0
29.0
14.5
14.5
14.5
6. Bolt and anchor the skillet securly to the floor, then seal the
bolt sand flanged feet with a silastic or equivalent compound.
7. If faucet is provided, connect water supply and check
operation.
8. Turn the power on and check for proper operation.
WARNING!:
Electrical and grounding connections must comply with
the appliance portions of The National Electrical Code
and/or other local codes.
ELECTRICAL CONNECTION:
NOTE!: Do not install in such a manner that a service person
cannot remove the control box cover.
• Connect unit to a branch circuit having a voltage and circuit
type specified on the name plate and of sufficient size to carry
load. The amps per line wire for the various voltage rating are
shown in table below.
NOTE!: Supply wires must be suitable for temperature of at
o
o
least 200
F (90
C). Additionally, all wiring must conform to
the requirements of local and national electric codes. Conduit
and fittings must be watertight.
• Connect ground wire from electrical service to ground lug.
• Ensure that skillet is firmly seated on fram before checking
connection and functioning of controls.
NOTE!: Unit is equipped with an interlock switch that shuts off
current to the heating elements when skillet pan is more
o
than (10
) above normal horizontal cooking position.
• Switch on current supply to unit. Check for proper fuctioning
of controls and heating elements (See page 4, Operating
Instructions).
SERVICE CONECTIONS:
• All Internal Wiring for the skillet is complete.
• Make service connections as indicated on page 2 and elec-
trical connections above.
• If a faucet is provided, connect the water supplies and check
for proper operation.
MODELS: 40P-STEL * 40P-STEM
EXPORT MODELS: 40P-STEL-LX * 40P-STEM-LX
3 pH, 4 Wire, 50Hz
Amps Per Line Wire
18 kW
220/380 Volt
18 kW
240/415 Volt
( EXPORT ONLY )
18 kW, 1 pH Unit, 60Hz
Amps Per Line
18 kW
18 kW
18 kW, 3 pH Unit, 60Hz
Amps Per Line
208 Volt
240 Volt
480 Volt
3
27.0
25.0
L # 1
L # 2
87.0
87.0
75.0
75.0
L # 1
L # 2
L # 3
50.0
50.0
50.0
43.0
43.0
43.0
22.0
22.0
22.0