6.3 Option
Item
Number of output
Output specification
Analog output
Output factor
Response time
Output ripple
Alarm factor:Voltage〔OR of each line (phase),Individual of each line (phase)〕, Alarm OFF.
Reset method:Automatic reset or Manual reset (Setting)
Output contact :No-voltage a contact (OR of each phase detection)
Contact capacity:AC250V 5A, DC125V 0.3A (Resistance load) AC250V 2A, DC125V 0.1A (Inductive load)
Alarm factor
Alarm output
Voltage
Function
Alarm reset
Maximum / Minimum value
reset
External
operation
All reset
input
Minimum operation pulse width
Rated input
● Caution on the use of external display selection input (option)
External power consumption is 0.4VA at AC110V or 1.4VA at AC220V or 0.4W at DC110V.
In case a relay or a switch is used for power-supply supply, please use the thing
of about 1mA of the minimum application loads.
3 circuits (Minus common)
DC4~20mA (Below 550Ω)
Voltage (Each phase or line), Frequency
1 second or less (Time within ±1% of final constant value.)
Within the double precision of accuracy (% for output span)
Possible to setting one of them.〕
Item
Measurement value ≧ Upper limit setting value,
Function
Measurement value ≦ Lower limit setting value,
Setting accuracy
±0.5% (% for full scale )
Setting range
Using a full scale as 150%. 30~150% (1% step)
Three types of following functions can be operated by adding a
voltage signal from the outside in addition to switch operation.
Alarm output is reset (output OFF).
Please refer to "4.3.5 Reset" about operation by the switch.
The maximum/minimum value is reset (it updates to the instantaneous
value at the time).
Please refer to "4.3.5 Reset" about operation by the switch.
Resets all of the alarm output and maximum/minimum value.
Please refer to "4.3.5 Reset" about operation by the switch.
300ms ,Continuation applying is possible.
Input rating becomes the same as that of auxiliary supply.
AC100/110V 0.4VA,AC200/220V 1.4VA,DC100/110V 0.4W
AC DC two ways.
Contact capacity:About 3mA (AC,DC100/110V),
Specification
Specification
Alarm display, Alarm output.
Alarm display, Alarm output.
About 6mA (AC200/220V)