Performance - Daiichi Electronics SVLC-110L Instruction Manual

Power line multi-meter (voltmeter)
Table of Contents

Advertisement

6.2 Performance.

Item
Intrinsic error
Accuracy of bar graph
Influence by
temperature
Compliance standard
Safety
Display updating time
Display device
Display composition
LCD view angle
Backlight
Auxiliary supply
Rush current
(Time constant)
Input consumption VA
Overload capacity
Insulation resistance
Voltage test
(Commercial frequency
withstand voltage)
JIS C 1102-1
JIS C 1111
Impulse voltage test
(Lightning impulse
withstand voltage)
JIS C 1111
22
Note(
) About white backlight.
The white backlight of this product is using white LED which combined the special phosphor and blue
LED. In the characteristics of this LED, color tone may be different for each product.
Reference to measure specification and intrinsic error
±10% (% for span)
Within accuracy by 23±10℃.
JIS C 1102-1:2007 ,JIS C 1102-2, -4, -7, -9:1997 , JIS C 1111:2006
JIS C 1010-1:2005
CATⅢ (The category to the measurement performed with fabric equipment)
Maximum circuit voltage 300V
Pollution degree 2 (Usually, environment which only contamination of non-conductivity
generates. However, temporary conductivity which originates in
dew condensation depending on the case occurs.)
About 1 second (Bar graph:0.25 seconds)
LCD
Number, Character,
Segment color:Black
For upper installation
Standard
(For lower view)
For lower installation
Special
(For upper view)
LED backlight:Green or White
Always-on, Auto off (after 5 minutes without operating), Always-off. Setting is possible.
White backlight can select brightness from five steps of 1 to 5. (
AC85~264V 50/60Hz 10VA (Rated voltage, AC100/110V,200/220V)
DC80~143V
6W (Rated voltage, DC100/110V) for both AC and DC uses
Rated voltage AC110V
Rated voltage AC220V
Rated voltage DC110V
Voltage circuit
0.25VA or less (110V) , 0.5VA or less (220V)
Voltage circuit
2 times 10 seconds, 1.2 times continuation of rated voltage.
1.5 times 10 seconds, 1.2 times continuation of rated voltage.
Auxiliary supply
In case of DC110V, 1.5 times 10 seconds, 1.3 times continuation of
rated voltage.
Between electric circuits and case (Earth).
Between input and output and auxiliary supply.
Between analog output and alarm output.
Between analog outputs are not insulation of minus common.
Between electric circuits and case (Earth).
Between input and output and auxiliary supply.
Between analog output and alarm output.
Between analog outputs are not insulation of minus common.
Between electric circuits and case (Earth).
(An analog output is excluded)
Between input and auxiliary supply.
(Grounds an output.)
Specification
Main monitor
Sub monitor (Left)
Sub monitor (Center),(Right)
Bar graph
Upper view angle 10°,Lower view angle 60°,
Right and left view angle 60°
Upper view angle 60°,Lower view angle 10°,
Right and left view angle 60°
2.2A or less (About 2.5ms)
4.4A or less (About 2.5ms)
1.6A or less (About 2.5ms)
39
4 digit, character height 11mm
4 digit, character height 6mm
4 digit, character height 6mm
20 dots
22
)
Above 50MΩ at DC500V megger
AC2210V (50/60Hz) 5 seconds
5kV 1.2/50μs Positive and negative
polarities, for each 3 time.
SVLC-212-175

Advertisement

Table of Contents
loading

Table of Contents