Setting Table - Daiichi Electronics SVLC-110L Instruction Manual

Power line multi-meter (voltmeter)
Table of Contents

Advertisement

5.2 Setting table

A setting item changes by the specification of a product, or the existence of an option.
(1) Important setting
Each parenthesized number shows a setting number and this number is displayed on the setting screen.
Items
Press SET and DISPLAY together for longer than 3 seconds
Sets the phase wire
of input circuit.
Select an phase wire by + and -
(311)
Selected phase wire is entered
Press SET and DISPLAY together for longer than 3 seconds
Sets the input
voltage (phase
Select a input voltage (at 1φ3W, phase voltage full-scale) by + and -
voltage full
scale).
Press SET
(312)
Press DISPLAY
Press SET and RESET/SHIFT together for longer than 3 seconds
Sets the
measurement range
Select a measuring range by + and -
of voltmeter
(211)
Selected measuring range is entered
Press SET for longer than 3 seconds
Sets the display
pattern
(111)
Returns to display mode.
Press SET and RESET/SHIFT together for longer than 3 seconds
Sets the output
factor of analog
Select an output factor by + and -
output 1 (AO1).
(221A)
Selected output factor is entered
Press SET and RESET/SHIFT together for longer than 3 seconds
Sets the output
factor of analog
Press RESET/SHIFT
output 2 (AO2).
(222A)
Selected output factor is entered
Press SET and RESET/SHIFT together for longer than 3 seconds
Sets the output
Press RESET/SHIFT
factor of analog
output 3 (AO3).
(223A)
Returns to display mode.
Press SET for longer than 3 seconds
Sets the factor
of alarm output.
Select an factor by + and -
(121AL)
Press DISPLAY
Press SET and RESET/SHIFT together for longer than 3 seconds
Sets the function
of external
Press MODE
operation input.
(231)
Selected function is entered
Setting and operation procedures
Selected input voltage (phase voltage full-scale) is entered
Returns to display mode.
Press SET
Selected display pattern is entered
Select an output factor by + and -
(222A)
Press RESET/SHIFT
(222A)
Press SET
Selected output factor is entered
Returns to display mode.
Select an function by + and -
(231)
Press SET for longer than 3 seconds
Press DISPLAY
Returns to display mode.
Press SET
Press DISPLAY
Select the display pattern by + and -
(111)
Press SET
Press DISPLAY
Press DISPLAY
Select an output factor by + and -
(223A)
Press MODE
(111)
(121AL)
Press SET
Selected factor is entered
Press SET
Press DISPLAY
Returns to display mode.
23
(311)
Press RESET/SHIFT
(311)
(211)
Returns to display mode.
Press DISPLAY
Press MODE
(211)
(221A)
Returns to display mode.
Press MODE
(211)
(221A)
Press SET
Returns to display mode.
Press MODE
(211)
(221A)
Press DISPLAY
Press MODE
(211)
(221A)
SVLC-212-175
Page
36
(312)
36,37
33
28,29
34
34
34
30
35

Advertisement

Table of Contents
loading

Table of Contents