Daiichi Electronics SQLC-110L Instruction Manual

Daiichi Electronics SQLC-110L Instruction Manual

Power line super multimeter
Hide thumbs Also See for SQLC-110L:

Advertisement

Quick Links

SQLC-220-086
INSTRUCTION MANUAL
POWER LINE SUPER MULTI-METER
SQLC-110L
3-Phase 3-Wire
Voltage, Current Input 2VT・3CT
Current Input 3CT
Analog Output
Hardware Model F

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SQLC-110L and is the answer not in the manual?

Questions and answers

Summary of Contents for Daiichi Electronics SQLC-110L

  • Page 1 SQLC-220-086 INSTRUCTION MANUAL POWER LINE SUPER MULTI-METER SQLC-110L 3-Phase 3-Wire Voltage, Current Input 2VT・3CT Current Input 3CT Analog Output Hardware Model F...
  • Page 2: Safety Concerns

     Aluminum electrolytic capacitors are used for products. Please energize the power supply within one year after purchase.  Countermeasures against troubles. If this product breaks down within the warranty period, it will be repaired by DAIICHI ELECTRONICS.  Disposal Please dispose this product as industrial waste (non combustible).
  • Page 3 SQLC-220-086  Operation Be careful with the following cautions during use.  Use the input within the rated range. Be careful since negligence of this caution may cause troubles of the unit.  There is a function to hold the maximum value and the minimum value in this product. The blackout this value will not be cleared by a power supply reset.
  • Page 4 SQLC-220-086 ① Voltage, current input (2/2) Default settings № Setting item 110V input 220V input Voltage upper limit value Instantaneous measurement detection Voltage lower limit value Action AUTO Backlight Brightness 3(Middle) Voltage range 6600V 220V Current range 100.0A Current display peculiar sensitivity 100.0A Active power polarity One side swing...
  • Page 5 SQLC-220-086 ② Current input № Setting item Default settings Pattern Pattern 15 Main monitor A(V) Sub-monitor (Left) A(U) Display combination Sub-monitor (Center) A(W) Sub-monitor (Right) - Bar graph A(V) Factor Reset form AUTO Alarm 1 Contact delay time 0 second Alarm output Test -...
  • Page 6: Table Of Contents

    SQLC-220-086 Content Safety concerns ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 1 1. Product outline ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6 1.1 Usage of product ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6 1.2 Features of product ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 6 2. The name and function of each part ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 7 3. Preparation 3.1 Installation ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 8 3.2 Connections ・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・・ 9 4.
  • Page 7: Product Outline

    SQLC-220-086 1. Product outline 1.1 Usage of product This single unit can measure and monitor demand current ×3, voltage ×3, current ×3, demand active power, active power, reactive power, power factor, frequency, watt-hour, var-hour, harmonic (voltage, current). From a low voltage circuit to a high voltage circuit, it is adapted for various usages, such as a measurement monitor of a receiving circuit, an energy conservation power monitor, a demand current measurement monitor, and a harmonic monitor.
  • Page 8: The Name And Function Of Each Part

    SQLC-220-086 2. The name and function of each part Bar graph display Scale markings The measurement value of the main Scale markings is automatically set in monitor is indicated by the analog. a measurement range. (Bar graph display of the measurement Upper limit (or lower limit) setting index value of sub-monitor is also possible.) An upper limit (or lower limit) set point...
  • Page 9: Preparation

    SQLC-220-086 3. Preparation 3.1 Installation Mount the unit by the attached M5 nuts to a panel of thinner than 10mm, referring to the following external dimensions drawing and panel cutout. Fasten these nuts with tightening torque 2.0 to 2.5N・m. ● Dimension diagram (1) Multi-meter ●...
  • Page 10: Connections

    SQLC-220-086 3.2 Connections Please perform connection after referring to the following wiring diagram.  Connection drawing ( 8 (1) 3φ3W (2VT,3CT) (2) Current input 3φ3W (3CT) U V W U V W AUX.SUPPLY LOAD ANALOG OUTPUT 1 ANALOG OUTPUT 2 AUX.SUPPLY ANALOG OUTPUT 3 LOAD...
  • Page 11: Operation

    SQLC-220-086 4. Operation  The function of switch Switch Function The integrated value of electric energy is changed to the usual display and an enlarged display. If it continues pushing 3 seconds or more, it will change to setting mode. In setting mode, it is used for the determination of a set point.
  • Page 12: The Screen Change And Function By Switch Operation

    SQLC-220-086 4.1 The screen change and function by switch operation This product changes various screens by switch operation. Here, the change step of the screen by switch operation is explained. Display mode DISPLAY Instantaneous measurement Phase (line) display change RESET/SHIFT Electric energy General No operation,...
  • Page 13: The Kind Of Display

    SQLC-220-086 4.2 The kind of display 4.2.1 Measurement display The measurement value display has the three following types of displays. The change of the measurement display element of the main monitor by switch operation and the change of the phase / line display of current / voltage is possible (temporarily). In a general measurement display, if switch operation is not performed for 10 minutes after changing a display element, it returns to the original measurement display element automatically.
  • Page 14 SQLC-220-086 Measurement Measurement Example of display Note Example of display Note factor factor var-hour var-hour “LAG” “LEAD” (Power (Power receiving, display receiving, display LAG) LEAD) var-hour var-hour “LAG” and “LEAD” (Power (Power ”-” and ”-” transmission, transmission, display display LAG) LEAD) ②...
  • Page 15: Alarm Detection Display

    SQLC-220-086 4.2.2 Alarm detection display The alarm value setting is a possible measurement factor (demand current and harmonic, etc.), it displays in case an input exceeds a set point. Besides the usual measurement display, the detected factor is displayed on a screen upper case. In addition, in case setting OFF (not use) as measurement factor, it does not detect.
  • Page 16 SQLC-220-086 Alarm factor Example of a display Alarm factor Example of a display Voltage Demand Upper Upper harmonic active limit limit power Detection display content Alarm setting value Alarm setting Detection Value display Setting as 11th content of bar graph (Distinguishes in under bar) Current harmonic...
  • Page 17: Setting Display

    SQLC-220-086 4.2.3 Setting display The display of various setting. There are three types of setting modes according to the contents of a setting. Refer to "5. Setting" for the operation in setting mode, and the detailed contents of a setting. ①...
  • Page 18: Operation

    SQLC-220-086 4.3 Operation 4.3.1 The main monitor display element change The measurement display element of the main monitor is changed. The change is performed by + -. In addition to general measurement display, this operation can be performed also (harmonic measurement display, maximum display and minimum display).
  • Page 19: Harmonic Measurement Display Change

    SQLC-220-086 4.3.3 Harmonic measurement display change General measurement display and a harmonic measurement display are changed. The change is performed by MODE . Whenever it pushes a switch, it changes general measurement display → Current harmonic measurement display → Voltage harmonic measurement display → General measurement display. This operation can also perform the maximum display and minimum display.
  • Page 20: Setting Value Check

    SQLC-220-086 4.3.5 Setting value check Voltage range (VT ratio), current range (CT ratio), and an alarm output set point are checked. Check by RESET/SHIFT and - pushed simultaneously. The change of a set point is carries out by + and - . In addition to general measurement display, this operation can be performed also (harmonic measurement display, maximum display and minimum display).
  • Page 21: Setting Mode 1

    SQLC-220-086 4.3.6 Setting mode Various kinds of setting are performed. Setting mode is three types, and operations are different. DISPLAY is pushed to return to the original measurement display. And, if a switch is not operated for 10 minute after a set point check, it will return to the original measurement display automatically. Operation and the contents of setting (detail) in setting mode, please refer to "5 Setting".
  • Page 22: Reset

    SQLC-220-086 4.3.7 Reset Various kinds of reset are performed. The kind of reset is as follows and operations are different, respectively. Reset of watt-hour integrated value (zero clear), Reset of maximum value and minimum value (it updates to the instantaneous value at the time), Alarm output reset (OFF of an alarm output (at the case of manual reset setting)).
  • Page 23 SQLC-220-086 (2) Reset of maximum value and minimum value Reset of the various measurement values of maximum value and minimum value is performed. This reset has two types of methods. (How to perform according to a measurement factor individual. How to reset all maximum values and minimum values by package.) a) Individual reset Reset of only a certain differential maximum value or the minimum value is performed.
  • Page 24 SQLC-220-086 (3) Alarm reset In case an alarm return method is set to “HOLD (manual return)”, an alarm output is reset (output OFF). (With an alarm output option) However, an output is not turned off by this operation, in case an alarm continues. And, this operation is unnecessary in case setting as "AUTO (automatic return)”...
  • Page 25: Setting

    SQLC-220-086 5. Setting 5.1 Function table This product has each function setting with a front switch. Setting mode 1. Function table (1) Current Setting Important Function Functional description Default setting Page input setting Set the display combination pattern 38 to Display pattern of the digital 4 displays and bar ○...
  • Page 26 SQLC-220-086 Setting mode 1. Function table (2) Current Setting Important Function Functional description Default setting Page input setting Current distortion Set the high-alarm value of current 141H ○ OFF (No operation) factor upper limit distortion factor. Current 5th Set the high-alarm value of current 142H conversion content ○...
  • Page 27 SQLC-220-086 Setting mode 2. Function table (1) Current Setting Important Function Functional description Default setting Page input setting Set the voltage measurement range 47 to Voltage range 6600V ( ○ (VT ratio). Set the current measurement range 47 to Current range ○...
  • Page 28 SQLC-220-086 Setting mode 2. Function table (2) Current Setting Important Function Functional description Default setting Page input setting Set the ON/OFF of voltage measurement Voltage ON/OFF display. Set the ON/OFF of current measurement Current ON/OFF ○ display. Set the ON/OFF of active power Active power ON/OFF measurement display.
  • Page 29 SQLC-220-086 Setting mode 3. Function table Current Setting Important Function Functional description Default setting Page input setting Input circuit phase 2VT・3CT product is 3-phase 3-wire ○ 3φ3W (Fixed) ○ line change (3φ3W) fixation. Input voltage Set the input voltage. 110V ○...
  • Page 30: Setting Table

    SQLC-220-086 5.2 Setting table Setting item changes by the specification of a product, or the existence of an option. (1) Important setting Each parenthesized number shows a setting number and this number is displayed on the setting screen. Items Setting and operation procedures Page Press SET and RESET/SHIFT together for longer than 3 seconds (211)
  • Page 31 SQLC-220-086 Items Setting and operation procedures Page Press SET for longer than 3 seconds Press MODE (111) (121AL) Set the factor of alarm output 1. Select an output factor by + and - Press SET Selected factor is entered (121AL) Press DISPLAY Returns to display mode.
  • Page 32 SQLC-220-086 (2) A combination except a display pattern. Each parenthesized number shows a setting number and this number is displayed on the setting screen. Items Setting and operation procedures Page Press SET for longer than 3 seconds Press RESET/SHIFT Set the display (111) (112) factor of main...
  • Page 33 SQLC-220-086 (4) Setting of reactive power measurement range. Each parenthesized number shows a setting number and this number is displayed on the setting screen. Items Setting and operation procedures Page Press SET and RESET/SHIFT together for longer than 3 seconds (211) Setting of Press RESET/SHIFT...
  • Page 34 SQLC-220-086 (8) Setting of analog output. Each parenthesized number shows a setting number and this number is displayed on the setting screen. Items Setting and operation procedures Page Press SET and RESET/SHIFT together for longer than 3 seconds Press MODE Set the analog (211) (221A)
  • Page 35 SQLC-220-086 (9) Setting of alarm output. Each parenthesized number shows a setting number and this number is displayed on the setting screen. Items Setting and operation procedures Page Press SET for longer than 3 seconds Press MODE Press RESET/SHIFT Set the return (111) (121AL) (122AL)
  • Page 36 SQLC-220-086 (11) Harmonic measurement setting Each parenthesized number shows a setting number and this number is displayed on the setting screen. Items Setting and operation procedures Page Press SET for longer than 3 seconds Press MODE Press MODE Press MODE Set the high-alarm (111) (121AL)
  • Page 37 SQLC-220-086 Items Setting and operation procedures Page Press SET for longer than 3 seconds Press MODE Press MODE Press MODE (111) (121AL) (131H) (141H) Press RESET/SHIFT Press RESET/SHIFT Press RESET/SHIFT Press RESET/SHIFT Set the detected (142H) (143) (144H) (145H) characteristics of 5th conversion Press RESET/SHIFT Press RESET/SHIFT...
  • Page 38: Setting In Detail Explanation

    SQLC-220-086 (14) Other, measurement setting Each parenthesized number shows a setting number and this number is displayed on the setting screen. Items Setting and operation procedures Page Press SET and DISPLAY together for longer than 3 seconds Press MODE Set the dead band (311) (321) of measurement...
  • Page 39 SQLC-220-086 (1) 111 to 116 Display combination setting ● Voltage, current input ( Sub-monitor Sub-monitor Sub-monitor № Pattern № Main monitor Bar graph (Left) (Center) (Right) Pattern 1 A(V) V(UV) A(V) Pattern 2 A(V) V(UV) cosφ A(V) Pattern 3 A(V) V(UV) A(V) Pattern 4...
  • Page 40 SQLC-220-086 Display combination setting RESET/SHIFT RESET RESET RESET RESET RESET Combination Sub-monitor Sub-monitor Sub-monitor Bar graph Main monitor /SHIF /SHIF /SHIF /SHIF /SHIF display (Left) (Center) (Right) factor Pattern 1 A(V):5 V(UV):1 Wh:14 Main monitor W:10 + - + - +...
  • Page 41 SQLC-220-086 ◆ 111 Combination display Select the factors to be measured and monitored by 4 digital Setting № New setting displays out of combination patterns. Current setting Set values are updated by SET . ◆ 112 to 115 Main monitor, Sub-monitor (left), Sub-monitor (center), Sub-monitor (right) Set these items for a display configuration other than combined patterns.
  • Page 42 SQLC-220-086 (2) 121AL to 128AL Alarm output setting 【with an alarm output option】 Various setting and an output test are performed about an alarm output. In case contact outputs 1 and 2 are alarm output specifications, the corresponding alarm output is setting. 122AL 123AL 121AL...
  • Page 43 SQLC-220-086 (3) 131H to 136 Demand detection setting The following operation method is setting. Demand current, action of demand active power, high-alarm value, time interval, power factor, demand active power. 133H 131H RESET/ RESET/ Demand current upper Demand current time Demand power upper SHIFT SHIFT...
  • Page 44 SQLC-220-086 ◆ 136 Power factor operation method Current setting The operation method of power factor measurement can be selected from 0 (instantaneous measurement) and 1 (averaging operator in a demand time interval). In case it is set as "1 (averaging operator in a demand time interval)", power factor measurement is calculated from the operation method of a power demand time interval and a demand active power meter.
  • Page 45 SQLC-220-086 ◆ 149 5th conversion detection characteristics. Alarm output, inverse time delay characteristics The detection characteristics of 5th conversion content can In case of upper limit setting value 35% be selected from A (Average mode) and I (inverse time delay (Voltmeter 3.5%) 10000 mode).
  • Page 46 SQLC-220-086 (6) 171 to 172 Backlight setting Set the action and brightness of backlight. RESET/ RESET/ Backlight action SHIFT Backlight brightness SHIFT New setting Current setting ◆ 171 Backlight action Select of backlight action to ON (always on) or AUTO (auto off) or OFF (always off).
  • Page 47: Setting Mode 2

    SQLC-220-086 5.3.2 Setting mode 2 SET and RESET/SHIFT 3 seconds 211 to 218 DISPLAY Measurement range setting MODE 221A to 228A DISPLAY Analog output setting MODE 241P to 244P DISPLAY Pulse output setting Display mode MODE (Measurement display) DISPLAY External operation input setting MODE 261 to 26C DISPLAY...
  • Page 48 SQLC-220-086 (1) 211 to 218 Measurement range setting Setting of measurement range in each measurement factors. RESET/ RESET/ Current display RESET/ Voltage range Current range intrinsic Power polarity SHIFT SHIFT SHIFT sensitivity RESET/ RESET/ SHIFT SHIFT RESET/ RESET/ RESET/ Power factor Reactive power SHIFT SHIFT...
  • Page 49 SQLC-220-086 ◆ 213 Current display intrinsic sensitivity Full scale Set the full scale of current meter. Changing the display specific The setting range is from 40 to 120% of the current range sensitivity changes the full scale and can be selected from the [Current display intrinsic of the bar graph.
  • Page 50 SQLC-220-086 ◆ 214 Active power polarity Select the display of active power from one side New setting swing (P) and both swings (-). Selection by + and - , set value is updated Both side swing by SET . display Default setting:P (One-side swing) Current setting +...
  • Page 51 SQLC-220-086 ◆ 216 Reactive power display intrinsic sensitivity Full scale Set the full scale of reactive power meter. Changing the display intrinsic The settable range is 30 to 115% of the reactive power range sensitivity changes the full scale of (VT ratio x CT ratio in the attached table), and can be selected the bar graph.
  • Page 52 SQLC-220-086 ◆ 217 Power factor range Power factor measurement range can be selected from 0.500 to 1.000 to 0.500 / 0.000 to 1.000 to 0.000. Change of this setting also sets the analog output range of a power factor automatically simultaneously. Selection by +...
  • Page 53 SQLC-220-086 (2) 221A to 228A Analog output setting 【with an analog output option】 Various setting of analog output is performed. New setting Setting No. Current setting 221A 222A 223A 224A RESET/ RESET/ RESET/ Ao1 output Ao2 output Ao3 output Ao4 output SHIFT SHIFT SHIFT...
  • Page 54 SQLC-220-086 ◆ 225A Current output intrinsic sensitivity New setting The current value set in the current range (212) is 100.0%, and the Setting No. Current setting setting range of the analog output specific sensitivity is 40.0% to 120.0% (0.1% step). Selection by +...
  • Page 55 SQLC-220-086 (3) 241P to 244P Pulse output setting 【With a pulse output option】 Various setting of a pulse output is performed. 241P RESET/ 242P RESET/ 243P RESET/ 244P Po1 output factor SHIFT Po1 pulse unit SHIFT Po2 output factor SHIFT Po2 pulse unit RESET/SHIFT New setting...
  • Page 56 SQLC-220-086 (4) 251 to 252 External operation input setting 【With an external operation input option】 Various setting of external operation input is performed. Setting factor New setting RESET/ External operation External operation SHIFT input 1 function input 2 function ALARM and RESET are RESET/ displayed by turns.
  • Page 57 SQLC-220-086 (5) 261 to 26C Measurement ON/OFF setting Measurement display ON/OFF setting of each measurement factor is performed. Selection by + and - , set value is updated by SET . Default setting:ON (All measurement factors) New setting Setting No. Current setting RESET/ RESET/...
  • Page 58: Setting Mode 3

    SQLC-220-086 5.3.3 Setting mode 3 SET and DISPLAY 3 seconds 311 to 312 DISPLAY Input circuit setting MODE 321 to 322 DISPLAY Measurement setting Display mode MODE (Measurement display) DISPLAY Analog output specification change setting MODE 341 to 348 DISPLAY Analog output adjustment MODE Setting mode 3...
  • Page 59 SQLC-220-086 (2) 321 to 322 Measurement setting Set the dead band of measurement display, and with or without of tidal current measurement. RESET/ New setting Dead band of measurement Tidal current measurement SHIFT RESET/SHIFT Current setting Setting No. ◆ 321 Measurement dead band Set the dead band of measurement display.
  • Page 60 SQLC-220-086 (General measurement) Display Analog output [mA] LEAD 0 to LAG 0/4 to 20mA LEAD 0 to LAG 0/LEAD 0 to LAG 0 LAG 0 cosφ=1 LEAD 0 Input Input φ=-90° φ=0° φ=90° φ=180° φ=270° φ=-90° φ=0° φ=90° φ=180° φ=270° [cosφ] [cosφ] LEAD...
  • Page 61 SQLC-220-086 (3) 331 Analog output specification change setting 【With analog output (DC0 to 5V or DC1 to 5V)】 Set the specification of analog output (DC0 to 5V/DC1 to 5V). Selection by + and - , set value is updated by SET . Default setting:DC1 to 5V or DC0 to 5V (Designation) New setting +...
  • Page 62: Specification

    SQLC-220-086 6. Specification 6.1 Specification and intrinsic error. Input circuit Input 3-phase 3-wire AC110V,220V common use. AC 5 A or AC 1 A 50/60Hz Designation Intrinsic error ( Maximum Minimum Measurement Measurement range / Current Analog output Digital measur- measur- Note item Display specification...
  • Page 63 SQLC-220-086 Intrinsic error ( Maximum Minimum Measurement Measurement range / Current Analog output measur- measur- Note Digital item Display specification input Pulse output display ement ement Harmonic 5th Voltage 0.0 to 20.0% UV-VW ±1.0% ±2.5% ○ Digital display is % conversion to 100% of content.
  • Page 64 SQLC-220-086 Item Specification Bar graph Bar graph display for the main-monitor factor. (Watt-hour and var-hour exclude) display A display of a sub-monitor factor can also be set. Current, Voltage :Effective value computing type. Demand ammeter :Arithmetic method according with bimetallic type. Demand active power meter:Arithmetic method according with bimetallic type, or average value within the demand time limit.
  • Page 65 SQLC-220-086 ● Measurement possible range. Measurement is possible range Measurement factor Input ( Display Analog output Limiter Low input cut Limiter Low input cut 101% of meter 0.5% of meter 101% of output 0.5% of output Voltage AC0 to 150V [AC0 to 300V] full scale full scale span...
  • Page 66: Specification, Performance

    SQLC-220-086 6.2 Specification, Performance Item Specification Accuracy Reference to measure specification and accuracy Accuracy of bar graph ±10 % ( % for span) Influence by temperature 23±10℃ within accuracy. JIS C 1102-1, -2, -3, -4, -5, -7:1997 ,JIS C 1111:1989 ,JIS C 1216:1995 , Compliance standard JIS C 1263:1995 About 1 second (Bar graph:0.25 seconds)
  • Page 67 SQLC-220-086 Item Specification (1) Oscillatory surge voltage When a damping vibration waveform (peak voltage 2.5kV, frequency 1MHz±10%) is repeatedly applied, the measurement error should be within 10% and no malfunction should occur. Voltage input circuit (Normal / Common) Current input circuit (Common) Auxiliary supply circuit (Normal / Common) (2) Square wave impulse noise If a noise (1μs, 100ns width) is repeated and added, a measurement error should be...
  • Page 68 SQLC-220-086 6.3 Option Item Specification Number of output 4 circuits Analog output no insulation type Analog output insulation type DC4 to 20mA (Below 550Ω) DC4 to 20mA (Below 550Ω) Output DC1 to 5V (Over 600Ω) DC0 to 1mA (Below 10kΩ) specification One of them is designated by DC0 to 5V/1 to 5V (Over 600Ω)
  • Page 69 SQLC-220-086 Item Specification Alarm factor:Demand current, Demand active power, harmonic 5th conversion content, Harmonic nth content, Distortion factor, Voltage, Alarm OFF. Possible to setting one of them. Reset form :Automatic reset or Manual reset (Setting) Output contact :No voltage normally open contact (a contact) (OR of each phase detection) Contact capacity:AC250V 8A, DC125V 0.3A (Resistance load) AC250V 2A, DC125V 0.1A (Inductive load) Alarm factor Item...
  • Page 70: Maintenance And Check

    SQLC-220-086 7. Maintenance and check 7.1 Trouble shooting Symptoms Possible causes Remedial measures The power supply is not supplied. Check the auxiliary supply. (Not connected. or voltage is low) Again, a power supply is supplied. Indicator does not display. Measurement display ON/OFF setting is set to OFF. Setting check.
  • Page 71: Appendix Table

    SQLC-220-086 Appendix table 1-1 Active power range, watt-hour multiplier rate table (3-phase 3-wire) V range 750.0kV 500.0kV 375.0kV 300.0kV 255.0kV 210.0kV 180.0kV 150.0kV 105.0kV 90.0kV 45.0kV 30.0kV Multiplier (VT550000/110V) (VT380000/110V) (VT275000/110V) (VT220000/110V) (VT187000/110V) (VT154000/110V) (VT132000/110V) (VT110000/110V) (VT77000/110V) (VT66000/110V) (VT33000/110V) (VT22000/110V) Multiplier rate rate...
  • Page 72 SQLC-220-086 Appendix table 1-2 Active power range, watt-hour multiplier rate table (3-phase 3-wire) V range 25.00kV 24.00kV 18.00kV 18.00kV 15.00kV 9000V 4500V 3000V 2400V 1500V 1200V 600V (VT880/110V) (VT480/110V) Multiplier (VT18400/110V) (VT16500/110V) (VT13800/110V) (VT13200/110V) (VT11000/110V) (VT6600/110V) (VT3300/110V) (VT2200/110V) (VT1650/110V) (VT1100/110V) Multiplier rate rate...
  • Page 73 SQLC-220-086 Appendix table 1-3 Active power range, watt-hour multiplier rate table (3-phase 3-wire) V range 600V 600V 500V 300V 150V Multiplier (VT460/110V) (VT440/110V) (VT380/110V) (VT220/110V) (110V) Multiplier rate rate A range 4.20 k 4.00 k 3600 k 2000 1000 (4.18) (3455) ×0.01 5.60 k...
  • Page 74 SQLC-220-086 Tokyo Office : 11-13, Hitotsuya 1-chome, Adachi-ku, Tokyo, 121-8639, JAPAN. TEL:+81-3-3885-2411 , Fax:+81-3-3858-3966 Kyoto Office : 1-19, Ichinobe-Nishikawahara, Jyoyou-shi, Kyoto, 610-0114, JAPAN. TEL:+81-774-55-1391 , Fax:+81-774-54-1353 DATE:November 28, 2020...